Plan Review Notes
Plan Review Notes For Permit 08010343
Permit Number 08010343
Review Stop B
Sequence Number 1
Notes
Date Text
2008-01-28 12:15:132004 FBC W/2007 REVISIONS
 ADDITION AND LEVEL 2 ALTERATIONS
  
 DENIED BY BUILDING
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3)SUBMIT ENERGY CALCULATIONS AS REQUIRED BY 2004 FBC
 SECTION 13-6. NOTE: IN ADDITION TO THE SIGNATURE OF THE
 PREPARER, THE OWNER/AGENT IS ALSO REQUIRED TO SIGN AND
 DATE THE FORM.
  
 4) SHOW COMPLIANCE OF THE BATHROOM WINDOWS WITH R308.4
 HAZARDOUS LOCATIONS.
 THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS
 LOCATIONS FOR THE PURPOSES OF GLAZING : 5. GLAZING
 IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS,
 SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS. GLAZING IN
 ANY PART OF A BUILDING WALL ENCLOSING THESE
 COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE
 GLAZING IS LESS THAN 60 INCHES (1524 MM) MEASURED
 VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE.
  
 5) PLEASE UPDATE THE CODE EDITION ON SHEETS 1 AND 2.
 THE CURRENT CODE IS THE 2004 FBC W/2007 REVISIONS.
  
 6) THE FOUNDATION NOTES ON SHEET 6 SPECIFY 2500 PSF AS
 THE REQUIRED SOIL BEARING CAPACITY AND THE DETAILS ON
 SHEETS 6,7,8,15 AND 16 SPECIFY THE SOIL COMPACTION AS
 2000 PSF. PLEASE CORRECT. 2004 FBC 106.1.1* CITY
 AMENDMENTS
  
 7) SHOW COMPLIANCE WITH SECTION 704 INSPECTION FOR
 TERMITES.
 IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE
 INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS
 AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING
 SHALL NOT BE LESS THAN 6 INCHES (152 MM). EXCEPTIONS:
 1.PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS
 THAN 5 / 8 INCH (17.1 MM) THICK ADHERED DIRECTLY TO THE
 MASONRY FOUNDATION SIDEWALL.
 2.ACCESS OR VEHICLE RAMPS WHICH RISE TO THE
 INTERIOR FINISH FLOOR ELEVATION FOR THE WIDTH OF SUCH
 RAMPS ONLY.
 3.A 4-INCH (102 MM) INSPECTION SPACE ABOVE PATIO
 AND GARAGE SLABS AND ENTRY AREAS.
  
 8) THE FOOTING SCHEDULE ON SHEET 6 REFERS DETAILS ON
 PAGE 6, HOWEVER, THESE FOOTING DETAILS ARE ON SHEET 7.
 PLEASE CORRECT
  
 9)THE KCC AND KECC COLUMN CAP CONNECTORS ARE
 INCORRECTLY SPECIFIED AS SIMPSON PRODUCTS AND THEY ARE
 MADE BY USP. THE UPLIFT VALUES ARE ALSO INCORRECT. THE
 KCC 44 HAS UPLIFT OF 3920 AND KECCLL HAS UPLIFT OF
 1750. SEE LATEST USP CATALOG OR THEIR WEBSITE.
  
 10) SUBMIT THE INSTALLATION DRAWINGS FOR THE STORM
 PANLES AS REQUIRED BY FAC RULE 9B-72. SPECIFY THE MOUNT
 TYPE, THE ANCHOR TYPE, ANCHOR SPACING, EDGE DISTANCE BY
 CIRCLING THE APPROPRIATE ITEMS ON THE INSTALLATION
 DRAWINGS AND TABLES.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW