Plan Review Notes
Plan Review Notes For Permit 08010249
Permit Number 08010249
Review Stop B
Sequence Number 20
Notes
Date Text
2008-09-18 13:40:18BUILDING PLAN REVIEW
 PERMIT: 08010249
 ADD: 295 LAKEVIEW AVE.
 CONT: KAST CONSTRUCTION
 TEL: (561)718-6141
 E-MAIL: [email protected]
  
 ARCH: PFVS/ GREGORY R PORTMAN
 TEL: (404)503- 5000
  
 STRUC: OMNJ/ THOMAS M BOG ACKI
 TEL: (561)835-9994
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 SUBMITTAL REVIEW:
 #093000-21 ULTRAFLEX 1 STANDARD POLYMER-ENRICHED TILE
 MORTER
 00-3000-5 PRECAST 4X4 CONCRETE SHOWER SILL
 ACTION: REVIEWED
  
 BUILDING PROVISO: THIS REVIEW IS FOR THE USE OF
 ULTRAFLEX 1 TO BE USED ON THE INSTALATIOJN OF THE
 PRECAST 4X4 INCH CONCRETE SHOWER SILL ONLY. THE
 CONTRACTOR HAS NOT PROVIDED WHAT TYPE OF MATERIALS WILL
 BE SUBMITTED FOR SOUND DEADENING. THE SUBFLOOR FOR THIS
 PRODUCT IS VERY LIMITED AS TO THE PRODUCT MUST COMPLY
 WITH 1207.3 STRUCTURAL-BORNE SOUND .
 1207.3 STRUCTURE-BORNE SOUND. FLOOR/CEILING ASSEMBLIES
 BETWEEN DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A
 PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE
 AN IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS
 THAN 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE
 WITH ASTM E 492.