Date |
Text |
2008-09-09 11:36:51 | BUILDING PLAN REVIEW |
| PERMIT: 08010249 |
| ADD: 295 LAKEVIEW AVE. |
| CONT: KAST CONSTRUCTION |
| TEL: (561)718-6141 |
| E-MAIL: [email protected] |
| |
| ARCH: PFVS/ GREGORY R PORTMAN |
| TEL: (404)503- 5000 |
| |
| STRUC: OMNJ/ THOMAS M BOG ACKI |
| TEL: (561)835-9994 |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2007 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| SUBMITTAL REVIEW |
| ACTION: DENIED |
| |
| LOUVERS & MULLIONS: |
| |
| 1) RULE 9B-72 REQUIRES PRODUCT APPROVALS THAT ARE |
| LISTED WITH EITHER THE FLORIDA STATE WEBSITE OR ANOTHER |
| APPROVED AGENCY SUCH AS UL OR MIAMI-DADE WITH THIRD |
| PARTY QUALITY ASSURANCE PROGRAM IN EFFECTTHAT IS |
| REGISTERED WITH THE STATE. |
| |
| 2) 1609.1.4(5) LOUVERS. LOUVERS PROTECTING INTAKE AND |
| EXHAUST VENTILATION DUCTS NOT ASSUMED TO BE OPEN THAT |
| ARE LOCATED WITHIN 30 FEET (9144 MM) OF GRADE SHALL |
| MEET REQUIREMENTS OF THE LARGE MISSILE TEST. |
| IMPACT-RESISTANT COVERINGS SHALL BE TESTED AT 1.5 TIMES |
| THE DESIGN PRESSURE (POSITIVE OR NEGATIVE) EXPRESSED IN |
| POUNDS PER SQUARE FEET AS DETERMINED BY THE FLORIDA |
| BUILDING CODE, BUILDING SECTION 1609 FOR WHICH THE |
| SPECIMEN IS TO BE TESTED. |
| |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |
| E-MAIL: [email protected] |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |