2008-01-09 11:16:07 | BUILDING PLAN REVIEW | | PERMIT: 08010041 | | ADD: 444 WEST RAILROAD AVE | | CONT: PBM DEVELOPMENT, INC. | | TEL: (561)368-2544 EXT22 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW: 1ST | | ACTION: DENIED | | 1-9-08 | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | 2)PROVIDE MORE INFORMATION FOR THE NEW MEZZANINE | | INCLUDING THE SQUARE FOOTAGE, SPIRAL STAIRS AND THE | | HANDRAILS. THE ENGINEERED SHOP DRAWINGS ARE ALSO | | REQUIRED AS STATED ON SHEET S1.0. | | | | 3)FBC 505.2 THE AGGREGATE AREA OF A MEZZANINE OR | | MEZZANINES WITHIN A ROOM SHALL NOT EXCEED ONE-THIRD OF | | THE AREA OF THAT ROOM OR SPACE IN WHICH THEY ARE | | LOCATED. | | | | 4)A FRONT ELEVATION DETAIL DRAWING OF THE MEZZANINE | | IS REQUIRED SHOWING THE OPENNESS IN ACCORDANCE WITH FBC | | 505.4 THE FLOOR LOAD OF THE MEZZANINE SHALL BE STATED | | ON THE DRAWINGS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] |
|