Date |
Text |
2008-01-08 16:55:48 | BUILDING PLAN REVIEW |
| PERMIT: 08010010 |
| ADD: 7310 GEORGIA AVE. |
| CONT: JEFFERY GOMERSALL BLDG CONTRACTOR |
| TEL: (561)718-1866 |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2007 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW: 1ST |
| ACTION: DENIED |
| |
| 1A)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| 2)PROVIDE AN EXISTING AND A PROPOSED FLOOR PLAN. THE |
| EXISTING PLAN SHALL SHOW ALL EXISTING WALLS AND |
| SYSTEMS. ON THE EXISTING PLAN INDICATE THE WALLS AND |
| SYSTEMS TO BE DEMOED. ON THE PROPOSED DRAWINGS SHOW ALL |
| NEW WALLS AND SYSTEMS. A WALL LEGEND INDICATING THE |
| DIFFERENT TYPES OF WALLS INCLUDING WALLS TO DEMO WILL |
| BE HELPFUL WITH THE REVIEW.CONSTRUCTION DOCUMENTS |
| SHALL BE OF SUFFICIENT CLARITY TO INDICATE THE |
| LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED. THE |
| DRAWING SHALL BE DIMENSIONED. WHAT ARE THE HEIGHT OF |
| THE STRUCTURE ABOVE AND THE SIZE OF EACH NEW BAY/ |
| SUITE? FBC. 106.1.1 |
| NOTE: WOOD FRAMING MEMBERS AND FURRING STRIPS ATTATCHED |
| DIRECTLY TO MASONARY OR CONCRETE WALLS SHALL BE OF |
| APPROVED NATURALLY DURABLE OR PRESERVATIVE-TREATED |
| WOOD. FBC 2304.11.2.2 |
| |
| 3)SPECIFY THE USE AND OCCUPANCY OF EACH BAY ALONG |
| WITH THE OCCUPANT LOAD. THE OCCUPANT LOAD SHOWN ON THE |
| DRAWINGS IS NOT CLEAR. CLARIFY. |
| |
| 4)TABLE 803.5 MINIMUM INTERIOR FINISH CLASSIFICATION; |
| PROVIDE INFORMATION BASED ON INTERIOR FINISH |
| REQUIREMENTS BASED ON OCCUPANCY |
| |
| MYRON JACOBS |
| BUILDING PLAN REVIEWER |
| (561)805-6726 |
| [email protected] |