Plan Review Notes
Plan Review Notes For Permit 07120585
Permit Number 07120585
Review Stop B
Sequence Number 1
Notes
Date Text
2008-01-04 10:36:05J. B. HGANOVER & CO.
 JAN. 04, 2008
 BUILDING PLAN REVIEW
 PERMIT: 07120585
 ADD: 525 OKEECHOBEE BLVD. SUITE 700
 CONT: PASS INTERNATIONAL
 TEL: (954)421-9000
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS,
 REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR
 REVIEW FOR PERMIT.
 IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF
 YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A
 THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID
 DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1*
 /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH
 ADMINISTRATIVE CODE.
  
 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE2007 SUPPLEMENTS. SHEET A-0.1.1
 PLEASE UPDATE APPLICABLE CODES TO THE CURRENT
 2007 FBC SUPPLEMENTS.
  
 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) THE SHELL BUILDING HAS NOT ACHIEVED A CERTIFICATE OF
 COMPLETION, THE CONTRACTOR FOR THIS TENANT SPACE IS
 DIFFERENT FROM THE "BASE BUILDING" AND WILL REQUIRE A
 LETTER FROM THE BASE BUILDING CONTRACTOR ALLOWING PASS
 INTERNATIONAL TO START WORK ON THIS TENANT SPACE BEFORE
 THE CERTIFICATE OF COMPLETION FOR THE BASE BUILDING HAS
 BEEN ISSUED. THE DEVELOPER AND BOTH G.C.'S WILL HAVE TO
 SUBMIT A LETTER STATING THAT THEY UNDERSTAND THAT ANY
 DISPUTE OVER RESPONSIBILITY DOES NOT RELIEVE THEM FROM
 THE JOINT RESPONSIBILITY TO COMPLY WITH THE BUILDING
 CODE.
 . 106.1.2 ADDITIONAL INFORMATION REQUIRED.
  
 5)PLEASE SEE DISCREPANCY BETWEEN THE SUITE NUMBER ON
 THE PERMIT APLICATION AND SHEET A-1.7.1. 106.1.2
 ADDITIONAL INFORMATION REQUIRED.
  
 6)SHEET A-3.7.1 PLEASE SEE DETAIL NUMBER (3) THE
 RECEPTION DESK INDICATES A GRANITE STONE TRANSACTION
 TOP WITH S S POST AT A HEIGTH OF 3'-6", PLEASE PROVIDE
 COMPLIANCE WITH 11-7.2 SERVICE COUNTERS.
  
 7) SHEET A-6.7.1 & A-6.7.2 BOTH INDICATE VARIOUS WALL
 DETAILS WHERE 2X4 WOOD BACKING WILL BE REQUIRED, PLANS
 DO NOT INDICATE THAT IN TYPE I & TYPE II BUILDING NO
 COMBUSTIBLE ALLOWED IN WALLS WITH THE EXCEPTION OF FIRE
 RETARDANT TREATED WOOD, SEE 603.1(1).
  
 8) SHEET A-7.7.1 DOOR SHCEDULE UNDER THE DOOR RATING
 COLUMN INDICATE FIRE RATED DOORS AS "C" LABEL, PLEASE
 SEE TABLE 715.3 RATES DOORS IN MINUTES AND HOURS.
  
  
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
  
  
  
  