 BUILDING PLAN REVIEW
 PERMIT: 07120567
 ADD: 1400 CENTRE PARK BLVD
 CONT: REGENCY COMMUNICATION INC.
 TEL: (865)300-3003
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 2) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 3)1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE
 BUILDING:
 1.BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR
 (KM/HR).
 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING
 CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7
 AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. 3.
 WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND
 DIRECTION SHALL BE INDICATED.
 4.THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF
 DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT.
 5.COMPONENTS AND CLADDING. THE DESIGN WIND
 PRESSURES IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE
 SELECTION OF EXTERIOR COMPONENTS AND CLADDING MATERIALS
 NOT SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN
 PROFESSIONAL. THIS INFORMATION SHALL BE CLEARLY
 INDICATED ON THE PLANS. PLEASE INDICATE THE EXPOSURE
 CATEGORY #3 ABOVE.
  
 4)ALL PLANS, SPECIFICATIONS, REPORTS, OR OTHER
 DOCUMENTS PREPARED OR ISSUED BY A DESIGN PROFESSIONAL
 AND BEING FILED FOR PUBLIC RECORD, SHALL CONTAIN THE
 DATE, SIGNATURE AND SEAL OF THE DESIGN PROFESSIONAL.
 ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME, ADDRESS
 AND LICENSE NUMBER ON EACH SHEET. SHEET T1 IS MISSING
 THE DATE SEAL AND SIGNATURE OF THE ENGINEER. THE SEAL
 OF P.E MARTIN H. SAHN IS NOT LEGIBLE ON THE SHEETS.
 F.A.C 61G15-23.002
  
 5)5)THE ADDRESS ON THE PLAN FOR MACTEC ENGINEERING
 AND CONSULTING, INC. NEEDS TO CORRESPOND WITH THE DBPR
 WEBSITE. SEE INFORMATION SHEET ATTACH.
  