Plan Review Notes For Permit 07120272 |
Permit Number |
07120272 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2007-12-20 15:13:36 | BUILDING PROVISO: | | TO BE IN PLACE AT C.O: | | | | PRIVATE | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | WITH A BARRIER COMPLYING WITH | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | ASTM D5034 100 LB TENSILE STRNGTH | | ASTM D3787 150 LB BALL BURST | | STRENGTH | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | EQUIPPED WITH A COVER DESIGNED TO | | MINIMIZE HEAT LOSS. | | | | PUBLIC POOLS | | 424.1.3.1.9 ALL PUBLIC POOLS SHALL BE SURROUNDED BY A | | MINIMUM 48" IN HEIGHT FENCE. A SELF LATCHING SELF | | CLOSING LOCKABLE GATE OF 48" MINIMUM HEIGHT WITH THE | | LATCH LOCATED NEAR THE TOP. SAFETY COVERS THAT COMPLY | | WITH ASTM F 1346 DO NOT SATIFY THIS REQUIREMENT. | | | | 13-412.1ABC2.6.2 POOL COVERS. HEATED POOLS SHALL BE | | EQUIPPED WITH A VAPOR RETARDANT POOL COVER ON OR AT THE | | WATER SURFACE. POOLS HEATED TO MORE THAN 90 DEGREES | | (F) | | SHALL HAVE A POOL COVER WITH A MINIMUM INSULATION VALUE | | OF R-12. |
|