2008-01-05 08:02:16 | |
| |
| DENIED |
| |
| 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| PER 108.3 FBC* |
| |
| 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| ADDED TO THE PERMIT APPLICATION FEES |
| |
| NOTE: FEES ARE DUE IN THE AMOUNT OF $208.69 FOR |
| INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS |
| REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW |
| |
| 3)PROVIDE 2 COPIES OF A RECENT SURVEY SHOWING THE |
| PROPOSED BUILDING/ADDITION WITH ALL SIDE AND REAR |
| SETBACK MEASUREMENTS TO THE PROPERTY LINES |
| |
| 4)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN |
| COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES. |
| THIS CAN BE ADDED TO THE LANDSCAPE PLAN REQUIRED BY |
| ZONING |
| |
| 5)IN AREAS OF QUESTIONABLE SOILS AS SHOWN IN THE |
| OFFICIAL ZONING MAP OF THE CITY OF WEST PALM BEACH, 2 |
| COPIES OF A SOIL TEST REPORT SHALL BE SUBMITTED PER |
| R401.4 FBC RES. |
| |
| 6)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT |
| COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR |
| BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND |
| APPROVED BY THE DESIGNER OF RECORD |
| |
| 7)PROVIDE MIN ROOF SHEATHING ATTACHMENT PER |
| R803.2.3.1 FBC RES. 4" EDGES AND 6' FIELD IN ZONES 1 & |
| 2 AND 4" EDGES AND FIELD IN ZONE 3 |
| |
| 8)PROVIDE MEAN ROOF HEIGHT AND TOP OF BEAM AT PORCH |
| ON SHEET A |
| |
| 9)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER |
| R313.1.1 FBC RES. |
| |
| 10)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF |
| EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE |
| SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. |
| ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG ******NO |
| PRODUCT APPROVALS WERE SUBMITTED FOR MULLIONS, AND |
| CONNECTORS AND STRAPS. IN LUE OF PRODUCT APPROVALS |
| STRAPS/CONNECTORS MAY BE LISTED IN A SCHEDULE ON THE |
| DRAWINGS COMPLETE WITH THE STATEWIDE PRODUCT APPROVAL |
| NUMBERS OR SUBMIT SIMPSON TIE'S COMPLETE FLORIDA INDEX |
| WITH CONNECTORS TO BE USED HIGHLIGHTED****** |
| |
| 11)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE |
| 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND |
| APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| *****THIS COMMENT FOR ANY NEW PRODUCT APPROVALS AND |
| SHOP DRAWINGS***** |
| |
| 12)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA |
| STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE. |
| THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG. |
| WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE |
| DENIED |
| ******NOT SUPPLIED FOR THE PGT DOORS, METAL TECH STORM |
| PANELS, CASTCRETE LINTELS |
| |
| 13)2 PRODUCT APPROVALS WERE SUBMITTED FOR THE STORM |
| PANELS METALTECH AND EASTERN METAL SUPPLY, WHICH ONE OF |
| THESE ARE BEING USED. ALSO CIRCLE THE METHOD THAT WILL |
| BE USED TO MOUNT THE PANELS AND FILL OUT A SHUTTER |
| SCHEDULE WITH KEY PLAN FOR THE OPENINGS PER WEST PALM |
| BEACH MEMO (SEE ATTACHED) |
| |
| 14)A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT IS REQUIRED PRIOR TO |
| A PERMIT BEING ISSUED |
| |
| BLDG PLAN REVIEW |
| ADRIAN MORSE |
| 561-805-6716 |
| |
| |
| |
| |
| |
| |
| |
| |