2007-12-31 09:49:56 | |
| DENIED |
| |
| |
| 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL |
| COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 |
| AMENDMENTS PER 106.1.1 FBC* |
| |
| 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| PER 108.3 FBC* |
| |
| 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| ADDED TO THE PERMIT APPLICATION FEES |
| |
| NOTE: FEES ARE DUE IN THE AMOUNT OF $3,782.59 FOR |
| REMAINING FEES, INCREASED VALUE AND STATE RADON FEES |
| THIS AMOUNT IS REQUIRED TO BE PAID PRIOR TO FURTHER |
| PLAN REVIEW |
| |
| 4)SURVEY AND SITE PLAN SIDE AND REAR SETBACK |
| MEASUREMENTS DO NOT MATCH EACH OTHER |
| |
| 5)PROVIDE CORRECT PROJECT ADDRESS ON THE DRAWINGS |
| (USE OF LABEL IS ACCEPTABLE), ALSO CLARIFY BUILDER AND |
| OWNER INFORMATION ON ENERGY CALC'S THEY STATE KOLTER |
| HOMES AS THE BUILDER |
| |
| 6)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA |
| STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE. |
| THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG. |
| WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE |
| DENIED |
| |
| 7) SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT |
| COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR |
| BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND |
| APPROVED BY THE DESIGNER OF RECORD ***PLEASE NOTE THAT |
| FLORIDA SHEETS WERE NOT SUBMITTED FOR PGT AND WAYNE |
| DALTON PRODUCTS AND THE FL#'S ARE WRITTEN AT THE TOP OF |
| THESE PRODUCT NOA'S*** |
| |
| 8)PRODUCT APPROVALS WERE NOT SUBMITTED FOR MULLIONS |
| THAT WILL BE USED ON SEVERAL DOOR AND WINDOW |
| INSTALLATIONS, ALSO PRODUCT APPROVAL FOR CASEMENT |
| WINDOWS WERE SUBMITTED BUT NONE ARE PRESENT ON THE |
| DRAWINGS, PLEASE CLARIFY |
| |
| 9)THE FIXED WINDOW IN THE DINING ROOM AREA IS 51 SQ |
| FT. AND EXCEEDS THE MAX ALLOWABLE SIZE OF 30.28 SQ FT. |
| IN THE FIXED WINDOW PRODUCT APPROVAL |
| |
| 10)CORRECT SECTION AND COLUMN DESIGNATIONS ON SHEETS |
| A/2 AND A/3 THAT REFER TO A SHEET 7 AND THAT ALSO HAVE |
| DETAIL AND SHEET NUMBERS REVERSED |
| |
| 11)CLARIFYFOUNDATIONFOR SCREEN WALL, SCHEDULE ON |
| A/2 STATES 12" X 24" FOOTING AND DETAIL OFBLOCK PIERS |
| ON SHEET A/5 SHOWS 30" X 30" PAD |
| |
| 12)CLARIFY SECTION J-6 ON SHEET A/2 AT GARAGE WALL |
| WITH DETAIL ON A/6 |
| |
| 13)CLARIFY DETAILS FOR FRAMED WALLS FROM MAIN ROOF AT |
| FRONT PORCH TO RAISED ROOF, ARE THESEDETAILS J-6, O-6 |
| AND N-6 IF SO SHOW THEORIENTATION OF SECTIONS ON THE |
| FLOOR OR ROOF PLAN. SHOW THAT BEAM ABOVE IS FRAMED INTO |
| ENTIRE PERIMETER WALL AS SHOWN ON ROOF FRAMING PLAN AND |
| IS IT BOXED OUT ON THE INSIDE ALL THE WAY AROUND AS |
| STATED ON SAME PLAN |
| |
| 14)REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS |
| OF NEW DRAWINGS WITH REVISIONS AND INCLUDE 1 COPY OF |
| THE OLD PAGES ONLY FOR REFERENCE. PLEASE RE-SUBMIT ANY |
| PAGES WITH THE IMPACT FEE STAMP |
| |
| 15)A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT IS REQUIRED PRIOR TO |
| A PERMIT BEING ISSUED |
| |
| NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 |
| AMENDMENTS |
| FBC* = WEST PALM BEACH ADMINISTRATIVE |
| AMENDMENTS TO FBC |