Plan Review Notes For Permit 07120207 |
Permit Number |
07120207 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2007-12-17 15:03:35 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.SPECIFY CONNECTION MOUNTING TYPE, FOR EXAMPLE, A1 | | THROUGH A6, SEE SHEET 2, ANCHOR CHART.ANCHOR SPACING | | REQUIREMENT CANNOT BE DETERMINED WITHOUT THIS | | INFORMATION. | | | | 2.YOU SPECIFY 1" EDGE DISTANCE, BLOCK SUBSTRATE.SEE | | ANCHOR CHART ON SHEET 2; ALL OF THE BLOCK SUBSTRATE | | CONNECTION TYPES REQUIRE AN EDGE DISTANCE GREATER THAN | | 1". | | | | 3.NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND | | OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 505.1. |
|