2007-12-07 14:31:45***FAILED***
  
  
 1)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C
 EQUIPMENT TO THE PROPERTY LINES.AS PER SECTION
 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4' INTO A REQUIRED SETBACK.
  
 2)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY.
  
 3)INDICATE SETBACK DIMENSIONS FROM PROPOSED
 ADDITIONS TO ALL PROPERTY LINES.NOTE:ALL NEW
 CONSTRUCTION MUST MEET CURRENT SETBACK REQUIREMENTS AS
 FOUND IN SECTION 94-94 OF THE CITY OF WEST PALM BEACH
 ZONING AND LAND DEVELOPMENT REGULATIONS:
 MINIMUM SETBACKS FOR PRINCIPAL BUILDING.
 A.FRONT: 25 FEET;
 B.CORNER: 12.5 FEET; TEN FEET IF LOT IS LESS THAN 60
 FEET WIDE;
 C.REAR: 15 FEET OR TEN PERCENT OF DEPTH, WHICHEVER
 IS LESS;
 D.SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
 4)INDICATE HEIGHT DIMENSIONS ON ELEVATIONS (SHEET
 A-2) FROM GRADE.
  
 5)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE BUILDING'S VALUE,
 LANDSCAPING SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDRS.PLEASE
 SUBMIT A LANDSCAPE PLAN SHOWING COMPLIANCE WITH SECTION
 94-442 AND 94-445 OF THE ZLDRS.
  
 6)THE PROPOSED ADDITION ON THE SW SIDE OF THE HOME
 DOES NOT MATCH BETWEEN THE SITE PLAN AND SHEETS
 A-2/A-3, PLEASE CLARIFY.PROVIDE A DEMOLITION PLAN
 SHOWING WHAT EXISTING IS TO BE REMOVED/DEMOLISHED.
  
  