Plan Review Notes For Permit 07110750 |
Permit Number |
07110750 |
|
Review Stop |
P |
Sequence Number |
4 |
|
Notes |
Date |
Text |
2008-01-17 09:30:10 | ****************PROVISO**************** | | A} PER FBC PLUMBING SECTION *708.3.5 BUILDING DRAIN | | AND BUILDING SEWER JUNCTION. THERE SHALL BE A TWO-WAY | | CLEANOUT NEAR THE JUNCTION OF THE | | BUILDING DRAIN AND THE BUILDING SEWER. | | | | B} PER FBC CHAPTER 11, SECTION *11-4.1.3(10)(A) WHERE | | ONLY ONE DRINKING FOUNTAIN IS PROVIDED ON A FLOOR, | | THERE SHALL BE A DRINKING FOUNTAIN WHICH IS ACCESSIBLE | | TO INDIVIDUALS WHO USE WHEELCHAIRS IN ACCORDANCE WITH | | SECTION 11-4.15 AND ONE ACCESSIBLE TO THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING.(THIS CAN BE | | ACCOMMODATED BY THE USE OF A HI-LO FOUNTAIN OR BY SUCH | | OTHER MEANS AS WOULD ACHIEVE THE REQUIRED ACCESSIBILITY | | FOR EACH GROUP ON EACH FLOOR). | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] | | | | |
|