Plan Review Notes For Permit 07110443 |
Permit Number |
07110443 |
|
Review Stop |
B |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2008-02-20 16:58:32 | NEWSINGLE FAMILY RESIDENCE BUILDINGREVISION | | CHECKLIST. | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | 1- NEED TO REVISE WIND EXPOSURE CLASSIFICATIONS TO "C" | | FROM "B" AS REQUIRED BY SEC. R301.2.1.4(3)OF 2004 | | FLORIDA RESIDENTIAL CODE.SEE ATTACHED COPY OF CODE | | SECTION.NEED TO REVISE INFORMATION ON SHEET T1 AND | | ALSO NEED TO REVISE OPENINGS DESIGN PRESSURES ON | | EXTERIOR ELEVATIONS AS REQUIRED BY TABLE R301.2.(3) OF | | 2004 FLORIDA RESIDENTIAL CODE TO VERIFY THAT PRODUCT | | APPROVALS WILL MEET THE REVISED DESIGN PRESSURES. | | | | 2- OWES $30.36 FOR REVISION UPDATED VALUATION. | | | | REMAINDER: | | PROVIDE INFORMATION REQUESTED ON PROVISO AS SOON AS | | POSSIBLE TO AVOID DELAYS OR CONFLICTS. | | | | JULIO GOMEZ | | BUILDING PLANSEXAMINER | | (561)805-6712 |
|