2008-03-24 16:37:04REVISED THREE PRODUCT APPROVALS
  
 DENIED BY BUILDING
  
 1) THE PRODUCT APPROVALS FOR THE SH-4000 PGT WINDOWS
 AND THE MASONITE STEEL DOORS HAVE BEEN REVIEWED FOR
 CODE COMPLIANCE.
  
 2) THE INSTALLATION SCHEDULE FOR THE ALUFAB STORM
 PANELS IS INCORRECT. THE MOUNT TYPE SPECIFIED IS FOR
 VERTICAL INSTALLATION. THE EDGE DISTANCE IS SPECIFIED
 AS 2" WHICH REQUIRES THE ANCHOR SPACING TO BE REDUCED
 BY HALF. PLEASE CORRECT.
  
 3) THE NUMBER OF PRODUCT APPROVALS REVISED IS THREE.
 THEREFORE AND ADDITIONAL $20.00 IN REVISION FEES IS
 DUE.
  