2007-11-06 17:43:12 | PROJECT: 3920 NORTH FLAGLER DRIVE/07110090 |
| |
| PROJECT DETAIL: MARBLE FLOORING INSTALLATION |
| |
| PLAN REVIEW: |
| |
| 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS |
| 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS |
| CITY OF WEST PALM BEACH/ FLORIDA BUILDING CODE, |
| ADMINISTRATION AMENDMENTS, CHAPTER 1, 2004 EDITION |
| |
| STATUS: FAILED |
| |
| COMMENTS: |
| |
| 1) PLEASE PROVIDE (2) COPIES OF THE ENGINEERING LETTER |
| REFERENCING THE TILE INSTALLATION. THE LETTER MUST BE |
| HARD COPIES AND SIGNED/SEALED PER THE FOLLOWING: |
| |
| |
| F.S.471.025SEALS.-- |
| |
| (1)THE BOARD SHALL PRESCRIBE, BY RULE, ONE OR MORE |
| FORMS OF SEAL TO BE USED BY LICENSEES. EACH LICENSEE |
| SHALL OBTAIN AT LEAST ONE SEAL IN THE FORM APPROVED BY |
| RULE OF THE BOARD AND MAY, IN ADDITION, REGISTER HIS OR |
| HER SEAL ELECTRONICALLY IN ACCORDANCE WITH SS. |
| 668.001-668.006. ALL FINAL DRAWINGS, SPECIFICATIONS, |
| PLANS, REPORTS, OR DOCUMENTS PREPARED OR ISSUED BY THE |
| LICENSEE AND BEING FILED FOR PUBLIC RECORD AND ALL |
| FINAL DOCUMENTS PROVIDED TO THE OWNER OR THE OWNER'S |
| REPRESENTATIVE SHALL BE SIGNED BY THE LICENSEE, DATED, |
| AND SEALED WITH SAID SEAL. SUCH SIGNATURE, DATE, AND |
| SEAL SHALL BE EVIDENCE OF THE AUTHENTICITY OF THAT TO |
| WHICH THEY ARE AFFIXED. DRAWINGS, SPECIFICATIONS, |
| PLANS, REPORTS, FINAL DOCUMENTS, OR DOCUMENTS PREPARED |
| OR ISSUED BY A LICENSEE MAY BE TRANSMITTED |
| ELECTRONICALLY AND MAY BE SIGNED BY THE LICENSEE, |
| DATED, AND SEALED ELECTRONICALLY WITH SAID SEAL IN |
| ACCORDANCE WITH SS. 668.001-668.006. |
| |
| 2) PLEASE SUBMIT DOCUMENTATION(2 COPIES) INDICATING |
| THAT THE REGUPOL ACOUSTICAL BARRIER HAS A STC RATING OF |
| NOT LESS THAN 50 AND COMPLIES WITH ASTM E-90 AND ASTM E |
| 492: |
| |
| 1207.2 AIR-BORNE SOUND. |
| WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| E 90. PENETRATIONS OR OPENINGS IN CONSTRUCTION |
| ASSEMBLIES FOR PIPING; ELECTRICAL DEVICES; RECESSED |
| CABINETS; BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR |
| EXHAUST DUCTS SHALL BE SEALED, LINED, INSULATED OR |
| OTHERWISE TREATED TO MAINTAIN THE REQUIRED RATINGS. |
| THIS REQUIREMENT SHALL NOT APPLY TO DWELLING UNIT |
| ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT |
| FITTING TO THE FRAME AND SILL. |
| 1207.3 STRUCTURE-BORNE SOUND. |
| FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| |
| |