Plan Review Notes
Plan Review Notes For Permit 07100789
Permit Number 07100789
Review Stop B
Sequence Number 3
Notes
Date Text
2007-12-28 15:47:02****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.THE VALUE OF THE JOB IS TO INCLUDE LABOR (NOTE THAT
 FEES ARE CHARGED BASED ON VALUE, NOT COST).$4800 HAS
 BEEN ADDED AS A LABOR COST TO REMOVE AND INSTALL 16
 WINDOWS, INSTALL 16 SHUTTERS.
  
 2.PLEASE KEEP THE PRESTORM PREPARATION PLAN IN THE
 PERMIT PACKAGE (REQUIRED FOR PERMIT ISSUANCE).
  
 3.ALL CHANGES TO THE PLAN ARE TO BE CLOUDED AND
 MARKED WITH A REVISION NUMBER.FAILURE TO DO THIS
 CAUSES FURTHER DELAYS.SEE CORRECTION #4.
  
 4.SOME WINDOWS HAVE NOW BEEN MARKED "EXISTING
 EGRESS".IT IS NOT CLEAR WHY THIS LANGUAGE HAS BEEN
 ADDED; IT DOES NOT APPEAR ON THE PLAN DATED 12/6/07.
 THE WINDOWS DO NOT COMPLY WITH EMERGENCY EGRESS
 REQUIREMENTS APPLICABLE TO DAY CARE ROOMS.THE
 RESPONSE LETTER STATES THAT EMERGENCY EGRESS IS NOT
 REQUIRED.WHY HAS THE PLAN BEEN REVISED IN THIS WAY?
  
 ALSO, THIS CHANGE HAS NOT BEEN CLOUDED.HAS ANYTHING
 ELSE ON THE PLAN BEEN REVISED AND NOT SHOWN AS A
 REVISION?PLEASE REMOVE THIS LANGUAGE FROM THE PLAN OR
 REVISE THE PLAN TO COMPLY WITH EGRESS REQUIREMENTS.
  
 5.THE SCOPE OF WORK IS NOT CLEAR.THE APPLICATION
 STATES "REMOVAL & INSTALLATION OF 11 WINDOWS".WINDOWS
 ARE MARKED 1, 2, "EXISTING EGRESS" OR "EXISTING".THE
 SHUTTER INSTALLATION SCHEDULE INCLUDES INFORMATION FOR
 OPENING TYPES 1 AND 2.
  
 A.REVISE INSTALLATION SCHEDULE TO CORRELATE WITH EACH
 OPENING.YOU MAY USE ONE LINE FOR SEVERAL OPENINGS BUT
 THE INFORMATION MUST BE CORRECT.THE OPENING SIZE ON
 THE INSTALLATION SCHEDULE SHOULD BE THE OPENING SIZE,
 NOT THE WINDOW SIZE.
  
 B.AREN'T THE WINDOWS IN OPENINGS "EXISTING EGRESS"
 AND "EXISTING" BEING REPLACED?SHUTTERS OVER THESE
 WINDOWS WAS AN ISSUE IN PREVIOUS PLAN REVIEWS, BUT THE
 PLAN NOW DOESN'T SHOW THEM AS HAVING SHUTTERS
 INSTALLED.CLARIFY WHICH WINDOWS ARE BEING REPLACED,
 WHICH OPENINGS WILL HAVE SHUTTERS INSTALLED.
  
 C.APPLICATION STATES 11 WINDOWS;PLAN SHOWS 16
 WINDOWS, 7 OPENINGS.THE PLAN SHOWS A LOT OF
 INFORMATION WHICH IS NOT REQUIRED, YET DOES NOT INCLUDE
 THE INFORMATION REQUIRED FOR PERMIT ISSUANCE.THE
 PERMIT APPLICATION SHOULD BE CONSISTENT WITH THE SCOPE
 OF WORK AND THE PLAN.PLEASE REVISE.
  
 6.FOR THE WINDOWS, SHUTTERS, AND MULLIONS, THE
 FOLLOWING IS REQUIRED:
  
 A.FLORIDA STATE OR LOCAL PRODUCT APPROVAL,
 WWW.FLORIDABUILDING.ORG
  
 B.EVALUATION REPORT
  
 C.INSTALLATION INSTRUCTIONS
  
 PREVIOUSLY, A MIAMIDADE NOA WAS SUBMITTED.NOAS
 INCLUDE THE EVALUATION REPORT AND THE INSTALLATION
 INSTRUCTIONS IN ONE DOCUMENT.HOWEVER, FLORIDA STATE
 PRODUCT APPROVAL WAS NOT SUBMITTED.NOW, ONLY
 MIAMIDADE NOA FOR THE SINGLE HUNG WINDOW HAS BEEN
 PROVIDED ALONG WITH TWO COPIES OF THE FLORIDA STATE
 PRODUCT APPROVAL, A SPEC SHEET FOR THE SHUTTERS (NO
 PRODUCT APPROVAL), AND NOTHING FOR THE MULLIONS.
 PLEASE PROVIDE ALL REQUIRED PAPERWORK FOR EACH ITEM;
 TWO SETS.
  
  
  
  
  