Plan Review Notes
Plan Review Notes For Permit 07100778
Permit Number 07100778
Review Stop B
Sequence Number 1
Notes
Date Text
2007-11-03 06:00:53BUILDING PLAN REVIEW
 PERMIT: 07100778
 ADD: 701 S. ROSEMARY AVE 1ST FLOOR
 CONT: HOOVER CANVAS
 TEL: (561)768-3508
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1)FBC 3105.1.1.1NO RIGID PART OF THE AWNING FRAME
 SHALL BE LESS THAN 7 FEET, 6 INCHES FROM THE GRADE
 DIRECTLY BELOW AND NO PART OF THE CLOTH DROP SHALL BE
 LESS THAN 7 FEET. INDICATE ON THE PLANS THE HEIGHT OF
 THE AWNING FROM THE FINISH GRADE TO THE BOTTON ON THE
 FRAME.
  
 2)FBC 106.1.1 CONSTRUCTIION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION,NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THE CODE AND RELAVANT
 LAWS AND ORDINANCES. THE DRAWINGS SHALL INDICATE
 CLEARLY WHERE ON THE BUILDING THE AWNINGS WILL BE
 INSTALLED.
  
 3)SEE THE ZONING REQUIREMENTSIN PACKAGE.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]