Plan Review Notes
Plan Review Notes For Permit 07100516
Permit Number 07100516
Review Stop Z
Sequence Number 1
Notes
Date Text
2007-10-22 14:18:12***FAILED***
  
  
 1)CLARIFY WHAT SURROUNDS PROPOSED POOL ON SURVEY, IF
 POOL ENCLOSURE REQUIREMENT IS MET BY A SCREEN ENCLOSURE
 OR FENCE, PLANS SHALL INDICATE SUCH.OTHERWISE: AS THE
 SURVEY DOES NOT SHOW AN EXISTING PERMANENT FENCE
 COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT SHALL
 BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO THE
 MINIMUM STANDARDS PROVIDED BELOW.
  
 PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B)+(C):
 B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE
 OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT
 ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF
 THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
 C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE
 THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND
 SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR
 WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF
 GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL
 SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH
 WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT
 SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.
  
 2)INDICATE POOL EQUIPMENT SETBACK DIMENSIONS FROM
 THE PROPERTY LINES.NOTE: MAY NOT PROJECT MORE THAN 4'
 INTO A REQUIRED SETBACK.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720