Plan Review Notes
Plan Review Notes For Permit 07100508
Permit Number 07100508
Review Stop E
Sequence Number 2
Notes
Date Text
2007-12-28 09:06:41 
 *** REDLINED PLANS***
  
 1) THE REQUESTED MINIMUM LIGHT FIXTURE(S) A MINIMUM OF
 ONE OUT FRONT OF DWELLING AND REAR OF DWELLING WAS NOT
 SHOWN ON PLANS. THIS WAS RED-LINED AS ONE FIXTURE AT
 EACH LOCATION OF SOME SORT WILL BE REQUIRED FORE EGRESS
 AND LIFE SAFETY BEFORE FINAL.
 210.70, 90.4, LS 101 7.8
  
 2) GE SYSTEM SHOWS STRUCTURAL STEEL, REDLINED TO FOOTER
 STEEL.
  
 3) ALL RECESSED LIGHTS TO BE INSTALLED SHALL MEET FBC
 13-606.1.ABC.1.2.4.
  
 4) LOW VOLTAGE SHOWN ON PLAN REQUIRES A SEPARATE
 PERMIT. PLANS SHOW PHONE AND CATV ONLY.
 ANY OTHER SYSTEMS INSTALLED (IE: ) SPEAKERS, WILL
 REQUIRED PLANS/LAYOUT OF LOCATIONS.
  
 IF THERE ARE ANY QUESTIONS ON THE ABOVE PLEASE DO NOT
 HESITATE IN CONTACTING THIS REVIEWER DIRECTLY.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]