Plan Review Notes
Plan Review Notes For Permit 07100186
Permit Number 07100186
Review Stop B
Sequence Number 2
Notes
Date Text
2007-10-30 10:29:59****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 FROM PREVIOUS LIST:
  
 1.ENGINEER IS TO EVALUATE SITE CONDITIONS FOR
 EXPOSURE B.NOTE THAT THE DEFINITION FOR EXPOSURE C
 HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  
 THE RESUB SHEET STATES "REDUCED BY 10% SPANS" BUT THE
 SAME SITE SPECIFIC WAS SUBMITTED.PLEASE EITHER DESIGN
 FOR EXPOSURE C, MARK THE CHARTS WITH DETAILS USED, OR
 HAVE ENGINEER STATE ON THE PLAN THAT THIS SITE IS
 WITHIN EXPOSURE B AND STATE WHY.THE ONLY PAPERWORK
 SUBMITTED WAS THE SAME CHARTS BUT WITH A NEW DATE; NO
 NEW INFORMATION PROVIDED.
  
  