2007-11-19 10:30:25 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| |
| FBCFLORIDA BUILDING CODE 2004 |
| FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| CODE |
| FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* |
| CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC |
| FLORIDA ADMINISTRATIVE CODE |
| FSFLORIDA STATUTE |
| |
| COMMENTS FROM PREVIOUS LISTS: |
| |
| 1.)YOU CANNOT APPLY FOR OWNER BUILDER PERMITS FOR |
| COMMERCIAL PROPERTIES. |
| |
| PLEASE READ FLORIDA STATUTE 489, "THE BUILDING OR |
| RESIDENCE MUST BE FOR YOUR OWN USE OR OCCUPANCY.IT |
| MAY NOT BE BUILT OR SUBSTANTIALLY IMPROVED FOR SALE OR |
| LEASE."MIGUEL LAVIN IS THE OWNER, EL LATINO AND |
| MIGUEL LAVIN BARBER SHOP ARE THE TENANTS.OWNER |
| BUILDER NOT ALLOWED FOR CORPORATIONS AS PER STATE OF |
| FLORIDA AND BUILDING OFFICIAL.THIS BUILDING IS RENTED |
| OR LEASED, HAS TWO TENANTS WHICH ARE CORPORATIONS. |
| OWNERSHIP OF THE COMPANIES WHICH LEASE OR RENT THE |
| SPACES IS NOT ADDRESSED IN THE OWNER BUILDER LAW. |
| |
| 2.)THE RAMP WHICH WAS REMOVED MUST BE REPLACED.SEE |
| FBC11-4.1.6(1)(B), NO ALTERATION SHALL BE UNDERTAKEN |
| WHICH DECREASES OR HAS THE EFFECT OF DECREASING |
| ACCESSIBILITY OR USABILITY OF A BUILDING OR FACILITY |
| BELOW THE REQUIREMENTS FOR NEW CONSTRUCTION AT THE TIME |
| OF ALTERATION.REVISE THE PLAN TO INCLUDE A RAMP OR |
| PROVIDE OTHER MEANS OF VERTICAL ACCESSIBILITY (ELEVATOR |
| OR LIFT). |
| |
| 3.)ALTERATIONS TO EXISTING BUILDINGS SHALL COMPLY |
| WITH THE FOLLOWING; IF EXISTING ELEMENTS, SPACES, OR |
| COMMON AREAS ARE ALTERED, THEN EACH SUCH ALTERED |
| ELEMENT, SPACE, FEATURE, OR AREA SHALL COMPLY WITH THE |
| APPLICABLE PROVISIONS OF SECTION 11-4.1.1 TO SECTION |
| 11-4.1.3, MINIMUM REQUIREMENTS FOR NEW CONSTRUCTION, |
| FBC11-4.1.6.SEE ALSO ITEM #2.REVISE PLAN TO PROVIDE |
| VERTICAL ACCESSIBILITY. |
| |
| 4.)THE GUARD IS TO COMPLY WITH FBC1012.THE HEIGHT |
| SPECIFIED IN THE NOTES (42 INCHES) AND "RAILING BLOW |
| UP" CONFLICTS WITH OTHER DETAILS ON THE PLAN, SUCH AS |
| NORTH ELEVATION, WHICH SPECIFY 2'10". |
| |
| 5.)IT DOES NOT APPEAR THE THE 1X2 PICKETS COMPLY WITH |
| THE DESIGN STRENGTH REQUIREMENTS OF FBC1607.PROVIDE |
| CALCULATIONS. |
| |
| 6.)SHOW THE DISTANCE BETWEEN THE TOP OF THE PICKETS |
| AND THE RAILING.FBC1012.3.SHOW DIMENSIONS AT |
| OPENINGS AT THE BOTTOM OF THE PICKETS. |
| |
| 7.)HANDRAIL EXTENSIONS AT THE BOTTOM DO NOT COMPLY |
| WITH FBC11-4.9.4(2). |
| |
| 8.)FOR THE RAILING WHICH IS NOT AGAINST THE WALL, |
| SHOW THE EXTENSION DIMENSIONS (THE SLOPED PORTION, THE |
| PORTION PARALLEL TO THE GROUND).FBC11-4.9.4(2). |
| |
| 9.)SHOW COMPLIANCE WITH FBC11-4.9.4(6).PROVIDE A |
| DETAIL FOR THE WALL MOUNTED RAIL AND A DETAIL FOR THE |
| HANDRAIL AT THE GUARD.AS DRAWN, THE HANDRAIL |
| EXTENSIONS ARE A HAZARD. |
| |
| 10.)SEE ATTACHED FS553.80(2)(B).A FEE WILL BE |
| CHARGED IF THE PLAN REVIEW COMMENTS ARE NOT ADDRESSED A |
| THIRD TIME AND MAY BE CHARGED ON PAST PLAN REVIEWS AS |
| THIS IS REQUIRED BY FLORIDA STATUTE. |
| |
| A SET HAS BEEN RETAINED. |
| |
| |
| |
| |
| |
| |
| |
| |