2007-10-02 22:29:33BUILDING PLAN REVIEW
 PERMIT: 07100039
 ADD: 700 S ROSEMARY AVE # 132
 CONT: ANDERSON- MOORE CONSTRUCTION
 TEL: (561)662-1819
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS,
 REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR
 REVIEW FOR PERMIT. IF YOUR PROJECT WILL REQUIRE A
 RESIDENT INSPECTOR OR IF YOUR PROJECT IS A THRESHOLD
 BUILDING REQUIRING A THRESHOLD INSPECTOR THEN (3) THREE
 SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED FOR PERMIT
 ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTSWEST PALM
 BEACH ADMINISTRATIVE CODE.
  
 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 2)TS SHEET AND ARCHITECTURAL SHEETS, ROSENTHAL
 ASSOCIATES, LLC ARE MISSING THEIR CERTIFICATE OF
 AUTHORIZATION. 481.219 F.S.CERTIFICATE OF
 AUTHORIZATION.THE TITLE BLOCK FOR ANY SHEET BEARING
 THE NAME OF AN ARCHITECT PRACTICING UNDER A FICTITIOUS
 NAME, A CORPORATION, OR A PARTNERSHIP, OFFERING
 ARCHITECTURAL SERVICES, SHALL INCLUDE THE CERTIFICATE
 OF AUTHORIZATION
 NUMBER.TS SHEET AND ARCHITEC) 61G1-16.004FL.
 ADMIN. CODE.PLANS PREPARED BY A REGISTERED ARCHITECT
 SHALL INCLUDE A TITLE BLOCK WHICH MUST:
 - STATE THE FIRM NAME, ADDRESS AND TELEPHONE
 NUMBER
 - STATE THE FIRM LICENSE NUMBER
 - STATE PROJECT NAME OR IDENTIFICATION
 - STATE DATE PREPARED
 - INCLUDE AN ORIGINAL SIGNATURE AND
 DATED SEAL
 - INCLUDE THE PRINTED NAME OF THE ARCHITECT SEALING
 THE PLANS.
  
 3) TS SHEET CODE AND STORE DATA: STATED THEWRONG
 BUILDING TYPE: TYPE BUILDING IS I-B THE 5 STORY PARKING
 GARAGE AND B-BLOCK ARE ONE BUILDING NOT TWO!
  
 4) TS SHEET GOVERNING CODES PLEASE CORRECT, THE 2004
 FBC WITH 2007 CODE REVISIONS WHEN SUBMIITED FOR PERMIT
 AFTER JULY 1, 2007.
  
 5) SHEET S1 COLUMBIA ENGINEERING IS ALSO MISING THEIR
 CERTIFICATE OF AUTHORIZATION,471.023 F.S. CERTIFICATE
 OF AUTHORIZATION.THE TITLE BLOCK FOR ANY SHEET
 BEARING THE NAME OF AN ENGINEER PRACTICING UNDER A
 FICTITIOUS NAME, A CORPORATION, OR A PARTNERSHIP,
 OFFERING ENGINEERING SERVICES, SHALL INCLUDE THE
 CERTIFICATE OF AUTHORIZATION NUMBER.
  
 6) SHEET S-1 INDICATES VARIOUS TIE DOWN STRAPS AS WELL
 AS A3.1 INDICATES THE USE OF BAHAMA STYLE SHUTTERS.
 PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION
 AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE
 SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT
 IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT
 HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR
 LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72.
  
 7) FBC 106.3 PRODUCT APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 8) ADDITIONAL INFORMATION REQUIRED, THE BAHAMA STYLE
 STORM SHUTTERS ARE THEY GOING TO BE DROPPED IN A CASE
 OF A HIGH WIND EVENT OR ARE THEY GOING TO BE LEFT IN
 THE OPEN FIXED POSITION?
 IF LEFT IN THE FIXED POSITION, THE PRODUCT APPROVAL
 HAVEN'T BEEN TESTED IN THIS MANNER AND WILL NEED AN
 ENGINEER TO DO A RATIONAL ANYLSIS ON THE LISTED
 FASTENERS AND FATENING SCHEDULE FOR 140 MPH. 106.1.2
 FBC
  
 9) COMMENT # 10 FROM CAPRIS' REVIEW STILL HAS NOT BEEN
 ADDRRESED, THE MIRROR IN THE HANDICAPPED DRESSING ROOM
 HAS NOT BEEN MOVED TO DIRECTLY ACROSS FROM THE BENCH,
 11-4.35.5 MIRROR. WHERE MIRRORS ARE PROVIDED IN
 DRESSING ROOMS OF THE SAME USE, THEN IN AN ACCESSIBLE
 DRESSING ROOM, A FULL-LENGTH MIRROR, MEASURING AT LEAST
 18 INCHES WIDE BY 54 INCHES HIGH (460 MM BY 1370 MM),
 SHALL BE MOUNTED IN A POSITION AFFORDING A VIEW TO A
 PERSON ON THE BENCH AS WELL AS TO A PERSON IN A
 STANDING POSITION.
  
 10A) THE HANDICAPPED DRESSING ROOM DOOR SWINGS INTO THE
 REQUIRED T-SHAPED SPACEPLEASE SEE 11-4.35.2 NO DOOR
 SHALL SWING INTO ANY PART OF THE REQUIRED TURNING
 SPACE.
  
 10B) NOTE THE E1.1 SHEET HAS THE HANDICAPPED BENCH ON A
 DIFFERENT WALL THAN THE A SHEETS, PLEASE CORRALATE,
 106.1.2 ADDITIONAL INFORMATION REQUIRED.
  
 10C) E1.1 THE WATER FOUNTAINS ALSO HAD NOT BEEN MOVED
 ON THIS SHEET, PLEASE CORRALATE, 106.1.2.
  
 11) SHEET A1.1 REAR EXIT DOOR, THE PLANS INDICATES
 HASHED LINES AND STORAGE AREA WALLS IN FRONT OF THE
 REAR EXIT, IS THE INTENT TO BLOCK OFF THE REAR EXIT?
 COMMON PATH OF TRAVEL FOR FIRE SPRINKLED BUILDINGS IS
 100' , THIS TENANT SPACE WOULD REQUIRE 2 EXITS.1013.3
 EXCEPTION(5).
  
 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS
 OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF
 CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST
 RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT
 BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC
 REQUIREMENT, THE SPECIFIC
 REQUIREMENT SHALL BE APPLICABLE.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
  
  
  
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved