2007-10-02 22:29:33 | BUILDING PLAN REVIEW |
| PERMIT: 07100039 |
| ADD: 700 S ROSEMARY AVE # 132 |
| CONT: ANDERSON- MOORE CONSTRUCTION |
| TEL: (561)662-1819 |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2007 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1STREVIEW |
| ACTION: DENIED |
| |
| 1A)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, |
| REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR |
| REVIEW FOR PERMIT. IF YOUR PROJECT WILL REQUIRE A |
| RESIDENT INSPECTOR OR IF YOUR PROJECT IS A THRESHOLD |
| BUILDING REQUIRING A THRESHOLD INSPECTOR THEN (3) THREE |
| SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED FOR PERMIT |
| ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTSWEST PALM |
| BEACH ADMINISTRATIVE CODE. |
| |
| 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 |
| DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN |
| THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF |
| MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY |
| WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE |
| SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS |
| A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE |
| SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| DETERMINED BY THE BUILDING OFFICIAL. |
| |
| 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT |
| ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 2)TS SHEET AND ARCHITECTURAL SHEETS, ROSENTHAL |
| ASSOCIATES, LLC ARE MISSING THEIR CERTIFICATE OF |
| AUTHORIZATION. 481.219 F.S.CERTIFICATE OF |
| AUTHORIZATION.THE TITLE BLOCK FOR ANY SHEET BEARING |
| THE NAME OF AN ARCHITECT PRACTICING UNDER A FICTITIOUS |
| NAME, A CORPORATION, OR A PARTNERSHIP, OFFERING |
| ARCHITECTURAL SERVICES, SHALL INCLUDE THE CERTIFICATE |
| OF AUTHORIZATION |
| NUMBER.TS SHEET AND ARCHITEC) 61G1-16.004FL. |
| ADMIN. CODE.PLANS PREPARED BY A REGISTERED ARCHITECT |
| SHALL INCLUDE A TITLE BLOCK WHICH MUST: |
| - STATE THE FIRM NAME, ADDRESS AND TELEPHONE |
| NUMBER |
| - STATE THE FIRM LICENSE NUMBER |
| - STATE PROJECT NAME OR IDENTIFICATION |
| - STATE DATE PREPARED |
| - INCLUDE AN ORIGINAL SIGNATURE AND |
| DATED SEAL |
| - INCLUDE THE PRINTED NAME OF THE ARCHITECT SEALING |
| THE PLANS. |
| |
| 3) TS SHEET CODE AND STORE DATA: STATED THEWRONG |
| BUILDING TYPE: TYPE BUILDING IS I-B THE 5 STORY PARKING |
| GARAGE AND B-BLOCK ARE ONE BUILDING NOT TWO! |
| |
| 4) TS SHEET GOVERNING CODES PLEASE CORRECT, THE 2004 |
| FBC WITH 2007 CODE REVISIONS WHEN SUBMIITED FOR PERMIT |
| AFTER JULY 1, 2007. |
| |
| 5) SHEET S1 COLUMBIA ENGINEERING IS ALSO MISING THEIR |
| CERTIFICATE OF AUTHORIZATION,471.023 F.S. CERTIFICATE |
| OF AUTHORIZATION.THE TITLE BLOCK FOR ANY SHEET |
| BEARING THE NAME OF AN ENGINEER PRACTICING UNDER A |
| FICTITIOUS NAME, A CORPORATION, OR A PARTNERSHIP, |
| OFFERING ENGINEERING SERVICES, SHALL INCLUDE THE |
| CERTIFICATE OF AUTHORIZATION NUMBER. |
| |
| 6) SHEET S-1 INDICATES VARIOUS TIE DOWN STRAPS AS WELL |
| AS A3.1 INDICATES THE USE OF BAHAMA STYLE SHUTTERS. |
| PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION |
| AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE |
| FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE |
| SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. |
| PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT |
| IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT |
| HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR |
| LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE |
| 9B-72. |
| |
| 7) FBC 106.3 PRODUCT APPROVALS. THOSE PRODUCT WHICH ARE |
| REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND |
| APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| |
| 8) ADDITIONAL INFORMATION REQUIRED, THE BAHAMA STYLE |
| STORM SHUTTERS ARE THEY GOING TO BE DROPPED IN A CASE |
| OF A HIGH WIND EVENT OR ARE THEY GOING TO BE LEFT IN |
| THE OPEN FIXED POSITION? |
| IF LEFT IN THE FIXED POSITION, THE PRODUCT APPROVAL |
| HAVEN'T BEEN TESTED IN THIS MANNER AND WILL NEED AN |
| ENGINEER TO DO A RATIONAL ANYLSIS ON THE LISTED |
| FASTENERS AND FATENING SCHEDULE FOR 140 MPH. 106.1.2 |
| FBC |
| |
| 9) COMMENT # 10 FROM CAPRIS' REVIEW STILL HAS NOT BEEN |
| ADDRRESED, THE MIRROR IN THE HANDICAPPED DRESSING ROOM |
| HAS NOT BEEN MOVED TO DIRECTLY ACROSS FROM THE BENCH, |
| 11-4.35.5 MIRROR. WHERE MIRRORS ARE PROVIDED IN |
| DRESSING ROOMS OF THE SAME USE, THEN IN AN ACCESSIBLE |
| DRESSING ROOM, A FULL-LENGTH MIRROR, MEASURING AT LEAST |
| 18 INCHES WIDE BY 54 INCHES HIGH (460 MM BY 1370 MM), |
| SHALL BE MOUNTED IN A POSITION AFFORDING A VIEW TO A |
| PERSON ON THE BENCH AS WELL AS TO A PERSON IN A |
| STANDING POSITION. |
| |
| 10A) THE HANDICAPPED DRESSING ROOM DOOR SWINGS INTO THE |
| REQUIRED T-SHAPED SPACEPLEASE SEE 11-4.35.2 NO DOOR |
| SHALL SWING INTO ANY PART OF THE REQUIRED TURNING |
| SPACE. |
| |
| 10B) NOTE THE E1.1 SHEET HAS THE HANDICAPPED BENCH ON A |
| DIFFERENT WALL THAN THE A SHEETS, PLEASE CORRALATE, |
| 106.1.2 ADDITIONAL INFORMATION REQUIRED. |
| |
| 10C) E1.1 THE WATER FOUNTAINS ALSO HAD NOT BEEN MOVED |
| ON THIS SHEET, PLEASE CORRALATE, 106.1.2. |
| |
| 11) SHEET A1.1 REAR EXIT DOOR, THE PLANS INDICATES |
| HASHED LINES AND STORAGE AREA WALLS IN FRONT OF THE |
| REAR EXIT, IS THE INTENT TO BLOCK OFF THE REAR EXIT? |
| COMMON PATH OF TRAVEL FOR FIRE SPRINKLED BUILDINGS IS |
| 100' , THIS TENANT SPACE WOULD REQUIRE 2 EXITS.1013.3 |
| EXCEPTION(5). |
| |
| 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS |
| OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF |
| CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST |
| RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT |
| BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC |
| REQUIREMENT, THE SPECIFIC |
| REQUIREMENT SHALL BE APPLICABLE. |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| |
| |
| |
| |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |
| E-MAIL: [email protected] |
| |
| |
| |
| |
| |
| |
| |
| |