2007-10-24 13:48:29***FAILED**** PLEASE PROVIDE THE FOLLOWING:
  
  
 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI).
 PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR
 NOI.
 YOU CAN GET NOI INFO FROM
 WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/
 NOTICE OF INTENT DEP FORM 62-621.300(4)(B),
 EFFECTIVE MAY 1, 2003
 2. PLEASE SHOW ON DRAWINGSDUMPSTER LOCATION ON DWG,
 LOCATION MUST BE ACCESSIBLE FOR PICKUP TRUCK. YOUR NOTE
 ON SHEET C-10, SAYS "DUMPSTER AND RECEPTACLES WILL BE
 MANUALLY ROLLED OUT........." YOU NEED TO GET AN
 APPROVAL FROM CITY'S SANITATION DEPT FOR PICKUP.
 3. PLEASE SHOW ON STORM WATER CALCULATTION THAT YOUR FF
 ELEVATION IS HIGH ENOUGH ANDHAVE CONSIDERED FLOOD
 ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA TO
 DETERMINE THE FIRST FLOOR ELEVATION, PARING LOT
 ELEVATION, CROWN OF THE ROAD ELEVATION, SIDEWALK ETC.
 ALSO, PLEASE SHOW WORST CROWN OF THE ROAD ELEVATION ON
 THE DRAWINGS.
 4. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA,
 GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREAYOU
 ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE
 THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH
 AND USED IN STORM WATER QUALITY CALCULATIONS.
 5. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE
 SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM
 ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE
 CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING
 ELEVATION, ETC ON DRAWINGS,
 6.IN YOURCALCULATION FOR EXFILTRATION TRENCHES, PER
 SFWMD YOU NEED TOTAKE WORST ONE EITHER 1" OVER ENTIRE
 AREA OR 2.5" CRITERIA FOR % OF IMPERVIOUS AREA. SO,
 PLEASE RECALCULATE LENGTH OF EXFILTRATION TRENCH. ALSO,
 PLEASE SHOW DRY DETENTION/WET DETENTION AREAS IN STORM
 WATER CALS I YOU HAVE THEM.
 7. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND
 YOUR SITE FOR STORM WATER DRAIN.
 8. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, &STORM
 WATER QUALITY CALCULATIONS. STORM WATER CALS MUST BE
 APPROVED FROM 100045TH STREET ENGINEERING SERVICES
 BEFORE WE ISSUE PERMIT.
 9. POLLUTION PREVENTION DETAILS:CLOTHES USED FOR SILT
 FENCE ETC., HEIGHT OF FENCE SHOULD BE HIGH(5' OR MORE)
 ENOUGH PER FDEP TO STOP DUSTPARTICLES.
 10. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH
 STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED.
  
 PLEASE RESPOND EACH OF THE ABOVE ITEMSIN DETAIL TO
 EXPEDITE YOUR PERMITTING PROCESS
  
 RASIK CHOKSHI805-6723


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved