Plan Review Notes
Plan Review Notes For Permit 07090648
Permit Number 07090648
Review Stop G
Sequence Number 4
Notes
Date Text
2008-12-19 10:19:45DENIED
 REFERENCE:
 FBC-2004 CHAPTER 1
  
 1. SHT P2.1 THE REVISIONS ON FILE FOR PUBLIC RECORD
 SHOW REVISIONS 07/25/07, 1, 3, 11/12/07, 4, 5, 6,
 REVISION 7 (DATED 4/7/08), 4/29/08, 5/22/08 & 9 DATED
 5/30/08 BUT THE SHEET SUBMITTED FOR REVISION HAS
 DELETED THE REVISION NUMBERS 7 & 9 FROM THE REVISION
 INDEX AND ADDED 2 REVISION DATED 6/19/08 & 10/20/08
 (INDICATED AS #SK-P1 BUT NOT FOUND). IN ORDER TO REVIEW
 THE REVISIONS, EACH REVISION AFTER REVISION 7 SHALL BE
 INDICATED WITH A REVISION NUMBER AND EACH REVISION
 SHALL BE CLOUDED ON THE FLOOR PLAN AND A REVISION
 NUMBER INDICATED ON EACH CLOUDED REVISION. REVISION 7
 NUMBER SHALL BE INDICATED ON THE REVISION INDEX FOR
 DATE 4/7/08. SECTION 106.1.3.
 FBC-2004 106.1.3 QUALITY OF BUILDING PLANS.
 BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH
 SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE
 MEDIUM. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS MANAGEMENT.
  
 2. SHT P2.1 THE GAS PIPING IS INCORRECT FOR THE 3/4"
 PIPE WITH 68 CFH. PER TABLE 402.4(1) 1" PIPE IS
 REQUIRED. -- THE GAS PIPING IS INCORRECT FOR THE 1 PIPE
 WITH 106 CFH. PER TABLE 402.4(1) 1-1/4" IS REQUIRED.
 THIS IS FOR THE GAS PIPING CHANGED AT THE PATIO
 HEATERS.
  
 3. SHT P3.1 THE REVISIONS ON FILE FOR PUBLIC RECORD
 SHOW REVISIONS 07/25/07, 1, 3, 11/12/07, 4, 5, 6 &
 REVISION 7 (DATED 4/7/08, BUT THE SHEET SUBMITTED FOR
 REVISION HAS DELETED THE REVISION NUMBER 7 FROM THE
 REVISION INDEX AND ADDED 5 REVISIONS DATED 4/29/08,
 5/22/08, 5/30/08, 6/19/08 & 10/20/08 (INDICATED AS
 #SK-P1 BUT NOT FOUND). IN ORDER TO REVIEW THE
 REVISIONS, EACH REVISION AFTER REVISION 7 SHALL BE
 INDICATED WITH A REVISION NUMBER AND EACH REVISION
 SHALL BE CLOUDED ON THE FLOOR PLAN AND A REVISION
 NUMBER INDICATED ON EACH CLOUDED REVISION. REVISION 7
 NUMBER SHALL BE INDICATED ON THE REVISION INDEX FOR
 DATE 4/7/08. SECTION 106.1.3.
 FBC-2004 106.1.3 QUALITY OF BUILDING PLANS.
 BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH
 SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE
 MEDIUM. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS MANAGEMENT.
  
 4. SHT P3.1 SHT P2.1 THE GAS PIPING IS INCORRECT FOR
 THE 3/4" PIPE WITH 68 CFH. PER TABLE 402.4(1) 1" PIPE
 IS REQUIRED. -- THE GAS PIPING IS INCORRECT FOR THE 1
 PIPE WITH 106 CFH. PER TABLE 402.4(1) 1-1/4" IS
 REQUIRED. THIS IS FOR THE GAS PIPING CHANGED AT THE
 PATIO HEATERS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  