2008-03-19 17:05:58 | *****DENIED***** | | | | THE FOLLOWING COMMENTS FROM THE PREVIOUS FIRE PLAN | | REVIEW STILL NEED TO BE ADDRESSED: | | | | 06.PLEASE PROVIDE FLAME SPREAD DETAILS FOR THE ENTRY | | CANOPY. | | | | 07.A DOOR NORMALLY REQUIRED TO BE KEPT CLOSED SHALL | | BE SELF-CLOSING OR AUTOMATIC CLOSING IN ACCORDANCE WITH | | 7.2.1.8.2 OF NFPA 101. | | | | 09.SPECIFY INTERIOR FINISH CLASSIFICATION FOR THE | | WALLS AND CEILINGS.INTERIOR WALL AND CEILING FINISH | | MATERIALS SHALL BE CLASS A OR CLASS B IN GENERAL | | ASSEMBLY AREA HAVING AN OCCUPANT LOADS OF MORE THAN | | 300. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING WHERE (ON THE APPROPIATE PLAN SHEET | | OR IN THE SPECIFICATIONS) EACH COMMENT WAS ADDRESSED | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|