2008-02-01 10:46:36 | KONA GRILL |
| 700 S ROSEMARY AVE SUITE# 100 |
| |
| BUILDING PLAN REVIEW |
| PERMIT: 07090648 |
| ADD: 700 S ROSEMARY AVE# 100 |
| CONT: IN MOTION BUILDERS, INC. |
| TEL: (954)698-0900 |
| FEB. 01/08 |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2007 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2NDREVIEW |
| ACTION: DENIED |
| |
| 1A)--- VERY IMPORTANT |
| STATEMENT --- |
| PLEASE DO |
| NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, |
| REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR |
| REVIEW FOR PERMIT. IF YOUR PROJECT WILL REQUIRE A |
| RESIDENT INSPECTOR OR IF YOUR PROJECT IS A THRESHOLD |
| BUILDING REQUIRING A THRESHOLD INSPECTOR THEN (3) THREE |
| SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED FOR PERMIT |
| ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTSWEST PALM |
| BEACH ADMINISTRATIVE CODE. |
| |
| 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 DRAWINGS & |
| SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO |
| THE TECHNICAL CODES "SHALL NOT BE CITED AS A WHOLE OR |
| IN PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED |
| AS A SUBSTITUTE FOR SPECIFIC INFORMATION". CONSTRUCTION |
| DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE |
| LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND |
| SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS |
| OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND |
| REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. |
| |
| 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT |
| ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. 2)SHEET |
| T1.1,CODE ANALYSIS PLEASE UPDATE THE 2004 TO THE 2007 |
| FBC, BUILDING WITH 2007 REVISIONS. |
| |
| 2-9) COMPLIED. |
| |
| 10) STRUCTURAL CALCULATIONS WERE NOT RESUBMITTED, |
| STRUCTURAL DESIGN CALCULATIONS ARE MISSING TITLE BLOCK |
| INFORMATION AS WELL AS NOT HAVING AN INDEX OF HOW MANY |
| SHEETS ARE IN THIS REPORT. FL S S 471.025. |
| |
| 11A) COMPLIED. |
| |
| 11B) 2ND REQUEST, WPB AMENDMENT 105.13.6. W.P.B. |
| CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD |
| BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY S. |
| 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS |
| REQUIRED BY THIS CODE. CONTACT HAROLD PISKURA MANAGER |
| OF THE SPECIAL INSPECTOR PROGRAM AT (561) 805-6711 FOR |
| FURTHER INFORMATION BEFORE THE PERMIT MAY BE ISSUED. |
| |
| 11C) 2ND REQUEST,W.P.B. AMENDMENT 105.13.4.4 ALL |
| PLANS FOR THE BUILDING WHICH ARE REQUIRED TO BE SIGNED |
| AND SEALED BY THE ARCHITECT OR ENGINEER OF RECORD |
| CONTAIN A STATEMENT THAT, TO THE BEST OF THE |
| ARCHITECT'S PR ENGINEER'S KNOWLEDGE, THE PLANS AND |
| SPECIFICATIONS COMPLY WITH THE APPLICABLE FIRE-SAFETY |
| STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN |
| ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE. |
| |
| 12) 2ND REQUEST, THE STRUCTURAL SHEET S0.0 FOUNDATION |
| DESIGN INDICATES THERE TO BE A GEOTECHNICAL SOILS |
| ENGINEER SHALL VERIFY THAT THE SOILS OF THE DESIGN |
| BEARING CAPACITY HAVE BEEN ENCOUNTERED. 1802.2.1 |
| QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING POWER OF |
| THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING VALUE |
| SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE |
| BUILDING OFFICIAL SHALL REQUIRE THAT THE NECESSARY |
| INVESTIGATION BE MADE. SUCH INVESTIGATION SHALL COMPLY |
| WITH THE PROVISIONS OF SECTIONS 1802.4 THROUGH 1802.6 |
| . |
| |
| 13-16) COMPLIED. |
| |
| 17)2ND REQUEST, FL BLD CODE 1609.1.4: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES |
| (FOR THRESHOLD BUILDINGS (3 COPIES) OF PRODUCT TESTING |
| REPORTS ,MISSING REPORTS ARE AS FOLLOWS: |
| 17A) FIXED WINDOWS, STOREFRONT |
| 17B) GLAZED EXTERIOR SWING DOOR, SINGLE AND PAIRS 17C) |
| DOORS W/ SIDELIGHTS |
| 17D) FOLDING DOOR SYSTEM |
| 17E) HURRICANE SHUTTER, HORIZONTAL ROLLER |
| 17F) TRUSS ANCHOR TYPE HARDWARE |
| 17G) LOUVER |
| 17H) ROOFING ASSEMBLIES W / INSULATION |
| |
| 18) 2ND REQUEST, PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED |
| TO COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| INFORMATION PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE |
| APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER |
| SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, |
| SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR |
| SITE SPECIFIC FORM PER RULE 9B-72. |
| |
| 19) 2ND REQUEST, WPB ADMIN CODE 106.3* PRODUCT |
| APPROVALS. THOSE PRODUCT WHICH ARE REGULATED BY DCA |
| RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY |
| THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL. |
| |
| 20) 2ND REQUEST, SHEET EX1.1 INDICATES POINTS WHERE THE |
| EXIT IS 3?-8? BUT THE WIDTH OF THE EGRESS PATH MAY BE |
| AS LITTLE AS 30? IN SOME AREAS, PLEASE PROVIDE THE |
| EGRESS PATH SHOWING THE FULL 44? WHERE IT SERVES AN |
| OCCUPANT LOAD GREATER THAN 50 AND 36? WHERE REQUIRED |
| FOR LESS THAN 50. 1024.9.1.1 THE MINIMUM WIDTH OF |
| AISLES SERVING SEATING AT TABLES SHALL BE 44 INCHES |
| (1118 MM). EXCEPTION: THIRTY-SIX INCHES (914 MM) WHERE |
| SERVING AN OCCUPANT LOAD OF NOT MORE THAN 50. |
| |
| 21-23) COMPLIED. |
| |
| 24) BUILDING PROVISO:A6.4 DETAIL # 2 & S5.0 FOR A |
| BRUSHED ALUMINUM CANOPY, THIS WILL REQUIRE SHOP |
| DRAWINGS, TO BE UNDER A SEPARATE PERMIT. THIS STRUCTURE |
| DOES NOT MEET THE REQUIREMENTS OF 3105, MUST MEET THE |
| 140 MPH PROVISIONS OF 1609.6. |
| |
| 25) COMPLIED. |
| |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |