Plan Review Notes For Permit 07090593 |
Permit Number |
07090593 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2007-11-17 09:23:17 | DENIED; | | 1. WOMEN'S LOUNGE HANDICAP SHOWER DOES NOT COMPLY. THE | | CLEAR FLOOR SPACE SHALL EXTEND 12" PAST THE SEAT. WALL | | IS IN THE WAY. SEE DETAIL ON PAGE P.2. THE STALL | | ENCLOSURE WILL INTERFERE WITH THE CLEAR FLOOR SPACE. | | SECTION 11-4.21.8. | | 2. SHOW LOCATION OF CONTROLS TO COMPLY WITH 11-4.21.5. | | 3. TOILET ROOM (BY UTILITY ROOM) SHALL MEET HANDICAP | | REQUIREMENTS SECTION 11-4.1.2(11). IF THIS IS A PRIVATE | | BATH AT IS REQUIRED TO BE ADAPTABLE. THIS BATHROOM DOES | | NOT MEET THOSE REQUIREMENTS. | | 4. SHOW DETAIL OF BREAK SINK. SHAL COMPLY WITH SECTIONS | | 11-4.24.1 THRU 11-4.24.7. SINK MUST HAVE A FRONTAL | | APPROACH WITH KNEE CLEARANCE PER 11-4.24.3. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|