2007-11-03 11:13:25 | |
| |
| DENIED |
| |
| THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM 1ST |
| REVIEW: |
| |
| 5)PROVIDE WIND DESIGN DATA ON DRAWINGS PER 1603.1.4 |
| FBC |
| *******NOTE WIND EXPOSURE NOT PRESENT ON |
| DRAWING******* |
| |
| 6)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 |
| FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER |
| AND OWNER/AGENT PRIOR TO SUBMITTAL. |
| ********NOTE THE ENERGY CALC'S DO NOT STATE THE AREA OF |
| NEW WALL R19 INSULATION, THE EAVE OVERHANG SIZE FOR THE |
| ADDITION IS INCORRECT AND THEY ARE NOT SIGNED BY THE |
| OWNER/AGENT.******* |
| |
| 7)SUBMIT ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH |
| R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE |
| INSTALLATION THAT HAVE BEEN REVIEWED AND APPROVED BY |
| THE DESIGNER OF RECORD. DRAWINGS TO BE SIGNED AND |
| SEALED BY TRUSS ENGINEER. |
| *******NOTE COMPLETE ORIGINAL SIGNED AND SEALED TRUSS |
| DRAWINGS WILL BE REQUIRED FOR SITE INSPECTOR BEFORE |
| INSPECTION******* |
| |
| 8)PROVIDE PRODUCT APPROVAL FOR WINDOW MULLIONS OR IF |
| SEPARATED BY STRUCTURE PROVIDE DETAIL. |
| *******NOTE NO PRODUCT APPROVALS WERE SUBMITTED FOR |
| WINDOW MULLIONS******* |
| |
| 9)PRODUCT APPROVAL FOR THE HARDIPLANK SIDING REQUIRES |
| HORIZONTAL FASTENING INTO WALL STUDS AT 16" O/C BUT |
| WALL SECTION ON SHEET 2 SHOWS FRAMING AT 24" O/C |
| ********NOTE DRAWINGS WERE NOT CHANGED TO REFLECT THE |
| MAXIMUM SPACING OF THE FRAMING MEMBERS FOR THE SIDING |
| PRODUCT OF 16" O/C******* |
| |
| 11)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE |
| 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND |
| APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| ********NOTE PRODUCT APPROVALS WERE NOT REVIEWED AND |
| APPROVED BY THE PERSONS RESPONSIBLE FOR |
| DRAWINGS******** |
| |
| REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS OF |
| NEW DRAWINGS AND INCLUDE 1 COPY OF THE OLD PAGES ONLY |
| FOR REFERENCE, PLEASE DON NOT REMOVE SHEET WITH IMPACT |
| FEE STAMP. |
| |
| NO NEW COMMENTS PENDING |
| |