Plan Review Notes For Permit 07080839 |
Permit Number |
07080839 |
|
Review Stop |
ENG |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2007-11-15 14:35:21 | **** FAILED **** | | | | 1.YOU NEED TO KEEP YOUR STORM WATER IN YOUR PROPERTY. | | YOU NEED TO KEEP STORM WATER INLET ATLEAST 5FEET | | INSIDE FROM PROPERTY LINE AWAY AND PLEASE SHOW ALL | | SLOPE INSIDE YOUR PROPERTY SO, STORM WATER STAYS IN | | YOUR PROPERTY.SO, PLEASE DESIGN AND SLOPEYOUR SITE | | SO THAT STORM WATER CAN BE ABSORBED IN YOUR OWN SITE. | | 2.YOU NEED TO CALCULATE STORM WATER QUALITY CALS USING | | BOTH CRITERIAONE,1'' OVER WHOLE SITE AND SECOND, | | 2.5" TIMES % OFIMPERVIOUS AREA ETC. | | | | RASIK CHOKSHI805-6723 |
|