Plan Review Notes
Plan Review Notes For Permit 07080515
Permit Number 07080515
Review Stop B
Sequence Number 1
Notes
Date Text
2007-08-29 14:15:582004 FBC WITH 2007 SUPPLEMENT
 CONSTRUCT NEW SINGLE FAMILY RESIDENCE
  
 DENIED BY BUILDING
  
 1)A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2)SUBMIT A COPY OF THE PAID RECEIPT FOR THE PALM
 BEACH COUNTY IMPACT FEES.
  
 3) REVISE THE CODE EDITION SPECIFIED ON SHEET T1 TO THE
 2004 FBC WITH 2007 SUPPLEMENT.
  
 4) THE REAR QUADRANT OF THE STRUCTURE ABUTS A LAKE AND
 A GOLF COURSE, WHICH HAS EXPOSURE C-TYPE TERRAIN FOR A
 DISTANCE OF MORE THAN 600 FEET. THEREFORE,THE
 STRUCTURE IS LOCATED IN EXPOSURE CATEGORY C. PER
 R301.2.1.4 EXPOSURE CATEGORY. 3. EXPOSURE C. OPEN
 TERRAIN WITH SCATTERED OBSTRUCTIONS, INCLUDING SURFACE
 UNDULATIONS OR OTHER IRREGULARITIES, HAVING HEIGHTS
 GENERALLY LESS THAN 30 FEET (9144 MM) EXTENDING MORE
 THAN 1,500 FEET (457.2 M) FROM THE BUILDING SITE IN ANY
 QUADRANT. THIS EXPOSURE SHALL ALSO APPLY TO ANY
 BUILDING LOCATED WITHIN EXPOSURE B-TYPE TERRAIN WHERE
 THE BUILDING IS DIRECTLY ADJACENT TO OPEN AREAS OF
 EXPOSURE C-TYPE TERRAIN IN ANY QUADRANT FOR A DISTANCE
 OF MORE THAN 600 FEET (182.9 M). SHORT-TERM (LESS THAN
 TWO YEAR) CHANGES IN THE PRE-EXISTING TERRAIN EXPOSURE,
 FOR THE PURPOSES OF DEVELOPMENT, SHALL NOT BE
 CONSIDERED OPEN FIELDS. WHERE DEVELOPMENT BUILD OUT
 WILL OCCUR WITHIN THREE YEARS AND THE RESULTANT
 CONDITION WILL MEET THE DEFINITION OF EXPOSURE B,
 EXPOSURE B SHALL BE REGULATING FOR THE PURPOSE OF
 PERMITTING. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY,
 GRASSLANDS AND OCEAN OR GULF SHORELINES. THIS CATEGORY
 DOES NOT INCLUDE INLAND BODIES OF WATER THAT PRESENT A
 FETCH OF 1 MILE (1.61 KM) OR MORE OR INLAND WATERWAYS
 OR RIVERS WITH A WIDTH OF 1 MILE (1.61 KM) OR MORE (SEE
 EXPOSURE D). PLEASE REVISE THE EXPOSURE CATEGORY
 SPECIFIED ON THE PLANS AND REVISE THE COMPONENT AND
 CLADDING PRESSURES TO EXPOSURE C.
  
 5) PLEASE INDICATE THAT THE INTERNAL PRESSURE
 COEFFICIENT ON T1 IS FOR BOTH POSITIVE AND NEGATIVE
 PRESSURES BY ADDING THE PLUS AND MINUS SIGNS. SEE
 ASCE7-02.
  
 6)SHOW COMPLIANCE WITH R302.1 EXTERIOR WALLS.
 EXTERIOR WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM)
 SHALL HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE
 RATING WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL
 NOT EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM
 AN ADJACENT PROJECTION OR WALL. THE LEFT SIDE OF THE
 STRUCTURE IS LOCATED 5 FEET FROM THE PROPERTY LINE.
 INDICATE ON THE PLANS THAT THE DISTANCE TO THE ADJACENT
 STRUCTURE IS MORE THAN 6 FEET OR THAT THE ADJACENT LOT
 IS VACANT.
  
 7) SUBMIT A DRAINAGE PLAN SHOWING COMPLIANCE WITH
 R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
 TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE
 GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM
 OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048
 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
  
 8) PROVIDE CONNECTION DETAILS FOR THE TOP AND BOTTOM OF
 THE 4 X 6 X 3/16 " T.S. COLUMNS BETWEEN THE LIVING ROOM
 WINDOWS. SPECIFY FASTENERS, ETC. FBC * 106.1.2
  
 9) PROVIDE A DETAIL OF THE WINDOW BUCK TO STEEL COLUMN
 DETAIL FOR THE 4X6 STEEL COLUMNS AT LIVING ROOM
 WINDOWS.
  
 10) PROVIDE AN ELEVATION OF THE EXTERIOR WALL AT THE
 BREAKFAST AND FAMILY ROOM. SPECIFY THE PRESSURES FOR
 THE WINDOW AT THE BREAKFAST ROOM.
  
 11) THE FL PRODUCT APPROVAL NUMBER LISTED IN THE ANCHOR
 SCHEDULE ON A3 FOR THE USP RT16 HURRICANE TIE IS
 INCORRECT. THE FL NUMBER FOR THIS CONNECTOR IS FL565,
 THE ONE LISTED IS FOR THE RT16 FLAT AND TWIST STRAP
 CONNECTORS. PLEASE CORRECT.
  
 12) THE DOUBLE OUT SWING FRONT DOORS, AS WELL AS, SOME
 OF THE OTHER PRODUCTS MAY NOT MEET THE INCREASED
 COMPONENT AND CLADDING PRESSURES OF THE EXPOSURE C
 CATEGORY. PLEASE REVIEW PRODUCT APPROVALS FOR ADEQUATE
 PRESSURES.
  
 13) SUBMIT RATIONAL ANALYSIS FROM A FLORIDA LICENSED
 ENGINEER FOR THE EXTERIOR 18" X 18" ACCESS DOOR TO THE
 WHIRLPOOL TUB MOTOR SHOWING THAT THE DOOR IS CAPABLE OF
 WITH STANDING THE WINDLOAD PRESSURES. SPECIFY THE
 ANCHOR TYPE, EMBED DEPTH, ETC. PROVIDE MANUFACTURER'S
 SPECIFICATIONS.
  
 -ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]
  
  
  
  
  
  
  