Plan Review Notes For Permit 07080505 |
Permit Number |
07080505 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2007-09-05 07:40:27 | | | BUILDING PLAN REVIEW | | PERMIT: 07080505 | | ADD: 580 VILLAGE BLVD | | CONT: G.A. RAY INC. | | TEL: (561)714-3740 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 1ST | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | 2)THE NEW RECEPTIONIST AREA SHALL MEET THE | | REQUIREMENTS OF SECTION 11-7. A PORTION OF THE MAIN | | COUNTER SHALL BE A MINIMUM OF 36 INCHES IN LENGTH AND A | | MAXIMUM HEIGHT OF 36 INCHES. SHOW COMPLIANCE. | | | | 3)FBC. 803.1 INTERIOR WALL AND CEILING FINISHES SHALL | | BE CLASSIFIED IN ACCORDANCE WITH ASTM E 84. THE NEW | | WALL AND CEILING SHALL HAVE A FLAME SPREAD OF CLASS A / | | B OR C. | | | | 4)SHOW THE COMMON PATH OF EGRESS TRAVEL ON THE | | DRAWINGS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] |
|