2007-08-29 18:00:56RESIDENTIAL ADDITION BUILDING FIRST REVIEW CHECKLIST.
 REVIEW DONE UNDER 2004 FLORIDA RESIDENTIAL CODE AND FBC
 2004 WITH 2007 REVISIONS.
  
 1-RECORDED NOTICE OF COMMENCEMENT WILL BE REQUIRED
 PRIOR TO ISSUING THE PERMIT AS REQ'D BY SEC. 713.13
 FLORIDA STATUTE.
  
 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.
 (561)233-5115)TO VERIFY IF IMPACT FEES ARE DUE. BRING
 BACK STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE
 DUE.
  
 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW.PERMIT VALUATION WAS UPDATED TO $86,732 ACCORDING
 TO THE ICC BUILDING VALUATION DATATABLE AS REQ'D BY
 SEC. 108.3 OF CITY AMENDMENTS TO FBC 2004. THEREFORE,
 OWES 1,187.17 FOR BUILDING VALUATION AND RADON FEES.
  
 4- PROVIDE SOIL TEST REPORT AS REQUIRED BY NOTES ON
 FOUNDATION PLAN AND SEC.R401.4 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 5- SPECIFY CONSTRUCTION TYPE ON PLANS AS REQ'D BY SEC.
 602.1 FBC 2004.
  
 6- IDENTIFYEXISTING ROOMS ADJACENT TO NEW ADDITION TO
 CHECK IF EGRESS OPENINGS ARE NOT BLOCKED AND CHECK
 COMPLIANCE WITH SEC. R310 OF 2004 FLORIDA RESIDENTIAL
 CODE.
  
 7- PLANS ARE MISSING THE SOUTH EXTERIOR ELEVATION.
 PROVIDE THIS ELEVATION. SEC. 106.1.2 CITY AMENDMENTS TO
 FBC 2004.
  
 8-PROVIDE ALL DIMENSIONS IN THE NEW SURVEY, INCLUDING
 THE BUILDING SETBACKS. SEC. 106.1.2 CITY AMENDMENTS TO
 FBC 2004.
 ALSO,SURVEY NEEDS TO HAVE ORIGINAL SURVEYOR SEAL AND
 SIGNATURE AS REQUIRED BY CHAPTER 472 FLORIDA STATUTE.
  
 9- ENERGY CALCULATIONS:
 A) PROVIDE 2 COPIES.
 B) PROVIDE REVISED FORM 600A-2004R.
 C) COMPLETE ALL INFORMATION ON TOP OF FORM.
 D) CLARIFY WHAT ARE ALL THE EXTERIOR AND ADJACENT
 WALLS SHOWN ON ITEM #9.
 E) PREPARER TO SIGN AND DATE FORM.
 F) OWNER/AGENT TO SIGN AND DATE FORM.
 G) OVERHANG HEIGHT IS INCORRECT. IT CAN'T BE 1. SEE
 EXTERIOR ELEVATIONS AND REVISE AS REQUIRED.
 H) REVISE BUILDING ORIENTATION. SEE PLANS AND SURVEY
 FOR CORRECT BUILDING ORIENTATION AND REVISE AS REQ'D.
  
 10- PROVIDE PRODUCT APPROVAL AS REQ'D BY DCA RULE 9B-72
 FOR:
 A) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS AND DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT
 APPROVAL COVERPAGE AND PAGE WHERE CONNECTOR IS
 SHOWN.
 B) EXTERIOR DOOR. NOA 01-1218.05 SUBMITTED EXPIRED
 ON 08/15/07. NEED TO PROVIDE CURRENT PRODUCT APPROVAL.
 C) SINGLE HUNG WINDOW PRODUCT APPROVAL 05-0729.03
 SUBMITTED EXPIRED ON 07/11/07. PROVIDE CURRENT PRODUCT
 APPROVAL.
 D) PRECAST LINTELS AS SPECIFIED ON PLANS.
 E) STORM SHUTTERS. AND, PROVIDE COMPLETE
 INSTALLATION SCHEDULE (SEE ATTACHED SAMPLE)AND KEY
 PLAN.ALSO,CLEARLY MARK ON SHUTTERS DRAWINGS
 SPECIFIC MOUNTING CONDITIONS (EG: WALL MOUNTED, ETC.)
 AND ANCHOR TYPE AND SPACING TO BE USED. SEC. 106.1.2
 CITY AMENDMENTS TO FBC 2004.
  
 11- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQ'D BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
 ***NOTE: PLEASE MAKE SURE NAME OF ENGINEER IS ON
 APPROVED AND REVIEWED STAMP.
  
 12- SHEET A1:
 A) REINFORCING STEEL SPECIFICATIONS SHOWN ON
 FOUNDATION SCHEDULE DON'T MATCH SPECS SHOWN ON
 FOUNDATION PLAN. REVISE AS REQUIRED TO MATCH.
 B) SPECIFY ATTIC ACCESS LOCATION AND SIZE TO COMPLY
 WITH SEC. R807 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 13- TYPICAL WALL SECTION A/A-2:
 A) SIZE OF FOOTING DOESN'T MATCH SIZE SHOWN ON
 FOUNDATION PLAN. REVISE AS REQ'D.
 B) REVISE SPECIFICATIONS FOR ROOF SHEATHINGNAILING
 SPACING ON ZONE 3 AREAS. SEE SEC. R803.2.3.1 OF 2004
 FLORIDA RESIDENTIAL CODE AND REVISE AS REQ'D.
 C) CLARIFY SPECS FOR INTERIOR FURRING STRIPS SIZE.
 IS IT REALLY 2X4'S AT 24" O.C. WITH R11 INSULATION?.
 THIS IS TYP. THE SPECS FOR A FRAMED BUILDING. REVISE
 CLARIFY AS REQUIRED.
 ALSO,COORDINATE INFORMATION WITH THEENERGY
 CALCULATIONS.
 D) SPECIFY FIREBLOCKING AS REQ'D BE SEC. R602.1.2 OF
 2004 FLORIDA RESIDENTIAL CODE.
 E0 CLARIFY/REVISE SPECS FOR STUCCO FINISH OVER METAL
 HIGHRIB LATH.ARE THESE THE SPECS FOR THE SOFFIT. IF
 SO, THEN SHOW ARROW POINTING TO CORRECT LOCATION.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER