2007-11-02 13:55:45 | PERMIT: 07071039 |
| ADD: 234 SOUTHERN BLVD |
| CONT: LEONARD ALBANESE & SONS BUILDERS, INC |
| TEL: (561)239-2034 |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2NDREVIEW/ NOV. 02-07 |
| ACTION: DENIED |
| |
| 1)--- VERY IMPORTANT STATEMENT |
| --- |
| PLEASE DO NOT |
| IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT |
| ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 3-7) COMPLIED. |
| |
| 8) 2ND REQUEST,A SINGLE SIGNED AND SEALEDGFA |
| INTERNATIONAL GEOTECHNICALREPORT WAS SUBMITTED, TWO |
| ORIGINAL SIGNED AND SEALED REPORTS ARE REQUIRED. NOTE |
| NOT THE SUMMARY OF DRAINAGE CALCULATIONS FROM NUTTING |
| ENGINEERING. |
| 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING |
| POWER OF THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING |
| VALUE SUPERIOR TO THAT SPECIFIED IN THIS CODE IS |
| CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE THAT THE |
| NECESSARY INVESTIGATION BE MADE. SUCH INVESTIGATION |
| SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1802.4 |
| THROUGH 1802.6 . |
| |
| 9)2ND REQUEST,THERE SEEMS TO BE A DISCREPANCY |
| BETWEEN THE PERMIT APPLICATION WORK TO BE COMPLETED |
| UNDER THIS BUILDING AND THE ENERGY EFFICIENCY CODE |
| ENERGY CALCS. |
| THE ENERGY CALCULATIONS ARE STATING THAT THEY ARE FOR A |
| SHELL BUILDING , THE DESIGNER OF RECORD IN THE LAST |
| RESPONCE INDICATED THIS TO BE A "COMPLETE BUILDOUT". |
| 106.1.2 ADDITIONAL INFORMATION REQUIRED. |
| |
| 10-14) COMPLIED. |
| |
| 15) 2ND REQUEST, DEALS WITH NON-ABSORBENT SURFACES |
| AROUND FIXTURES. THE EPOXY PAINT ON DRYWALL HAS NOT |
| BEEN ESTABLISHED AS A NON-ABSOBENT MATERIAL SINCE IT |
| CAN GET NICKS IN THE SURFACE THROUGH OUT THE LIFE TIME |
| OF THE INSTALATION. |
| PLEASE COMPLY WITH 1210.2 FOR WALLS , WITH SMOOTH, HARD |
| NONABSORBENT SURFACES TO A HEIGHT OF 4'-0" FOR FIXTURES |
| THATTHE WALLS CAN BE ADVERSELY AFFECTED BY MOISTURE. |
| |
| 16)-17) COMPLIED. |
| |
| 18) 2ND REQUEST, SHEET S-01& S-06 NOTES NUMBER THREE |
| REINFORCING STEEL. VERTICAL WALL REINFORCINGS-01 |
| INDICATES VERTICAL REINFORCEMENT @ NEXT TO ALL |
| OPENINGS, AND CORNERS, BUT IN A STRAIGHT WALL THERE IS |
| NO CENTER TO CENTER SPACING PROVIDED ON |
| SHEET S-01 OR IN THE NOTES ON S-06. RECITING THE CODE |
| OR A REFERENCE STANDARD DOES NOT PROVIDE THE |
| INFORMATION NEEDED FOR THE INDIVIDUAL WHO IS IN THE |
| FIELD.106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 |
| DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN |
| THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF |
| MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY |
| WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE |
| SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS |
| A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE |
| SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| DETERMINED BY THE BUILDING OFFICIAL. ACI 530- 8.1.2 |
| DETAILS OF REINFORCEMENTSHALL BE SHOWN ON PLANS OR |
| COVERED BY NOTES ON THE PROJECT DRAWINGS. |
| |
| 19-22) COMPLIED. |
| |
| 23) BUIULDING PROVISO: LIGHT POLES,TO BE SUBMITTED AS |
| SHOP DRAWINGS |
| |
| 24)FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, |
| PLEASE PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, |
| MISSING REPORTS ARE AS FOLLOWS: |
| |
| 24 E) TRUSS ANCHORS- NO REPORT SUBMITTED |
| |
| 25-27) COMPLIED. |
| 28)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, |
| IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE |
| ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE |
| PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 29) BUILDING PROVISO:109.3.10* IMPACT OF CONSTRUCTION. |
| ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL |
| BE PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT |
| THE CONDITION OF ADJACENT PROPERTY, UNLESS SUCH |
| ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY PURSUANT |
| TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, UNDER |
| TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY |
| OWNER. THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL |
| OF DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND |
| THE STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION |
| ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE |
| WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY |
| REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH |
| ENGINEERING STANDARDS TO PRESERVE THE |
| POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, |
| DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW |
| RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, |
| PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING |
| PROPERTIES RESULTING |
| IN A DECREASE IN EXCESS OF 800SQ FT OF PERMEABLE LAND |
| AREA ON ANY PARCEL SHALL AS A PERMIT CONDITION, PROVIDE |
| A PROFESSIONALLY PREPARED DRAINAGE PLAN CLEARLY |
| INDICATING COMPLIANCE WITH THIS PARAGRAPH. UPON |
| COMPLETION OF THE |
| IMPROVEMENT, A CERTIFICATION FROM A LICENSED ENGINEER |
| SHALL BE SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE |
| APPROVAL OF THE FINAL INSPECTION. |
| |
| 30) BUILDING PROVISO: 109.3.10.1 HURRICANE PROTECTION. |
| IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW |
| CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO |
| REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION |
| SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN |
| ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN |
| LIFTED. ALL SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND |
| DEBRIS SHALL BE EITHER REMOVED FROM THE CONSTRUCTION |
| SITE OR SECURED IN SUCH A MANNER AS TO MINIMIZE THE |
| DANGER OF SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND |
| DEBRIS CAUSING DAMAGE TO PERSONS OR PROPERTY FROM HIGH |
| WINDS. ANY PERSONS WHO FAILS TO COMPLY TO REMOVE OR |
| SECURE THE CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS |
| WITHIN 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED |
| SHALL BE SUBJECT TO A FINE NOT TO EXCEED $500.00. IN |
| ADDITION TO THE ABOVE, A LICENSED CONTRACTOR WHO |
| VIOLATES THIS SECTION SHALL BE SUBJECT TO DISCIPLINE |
| PURSUANT TO SECTION 113 OF THIS CHAPTER. |
| |
| 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS |
| OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF |
| CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST |
| RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT |
| BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC |
| REQUIREMENT, THE SPECIFIC |
| REQUIREMENT SHALL BE APPLICABLE. |
| |
| |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| |
| |
| |
| |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |
| E-MAIL: [email protected] |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECODS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |