Date |
Text |
2007-09-15 17:44:42 | DENIED |
| REFERENCE: FBC-2004 PLUMBING |
| FBC-2004 BUILDING |
| FBC-2004 CHAPTER 1 |
| FLORIDA ADMINISTRATIVE CODE |
| FLORIDA STATUTES |
| |
| 1. SHTS CS-1 AND ALL ARCHITECTUAL SHEETS. THE PRINTED |
| NAME OF THE PERSON SEALING THE DOCUMENT SHALL BE IN THE |
| TITLE BLOCK OF EACH SHEET. FAC 61G1-16.004(6) & FS |
| 481.2055. PLEASE INDICATE THE PRINTED NAME. |
| |
| 2. SHT 1 OF 1, (DCES), SHALL BE SIGNED, SEALED AND |
| DATED PER SECTION 106.1. |
| |
| 3. SHT A-201 PER TABLE 403.1 THREE WATER CLOSETS AND |
| THREE LAVS ARE REQUIRED FOR THE BUSINESS OCCUPANCY AT |
| 7260SF. ONLY 2 W/C'S AND 2 LAVS WERE PROVIDED. PLEASE |
| SHOW COMPLIANCE WITH TABLE 403.1 REQUIEMENT. |
| |
| 4. SHT A-901 ROOM FINISH SCHEDULE. ROOMS 114 & 115. THE |
| WALLS WITH IN 2 FEET OF A WATER CLOSET SHALL HAVE A |
| SMOOTH, HARD, NONABSORBENT SURFACE UP TO 4 FEET. THE |
| SCHEDULE INDICATES PAINTED GWB. PAINTED SURFACES DOES |
| NOT COMPLY WITH THE REQUIREMENT FOR A HARD SURFACE. |
| PLEASE SHOW COMPLIANCE WITH SECTION 1210.2. |
| |
| 5. SHTS S-01 THRU S-06. ENGINEER SHALL LEGIBLY INDICATE |
| THEIR NAME ON EACH SHEET. ALSO THE CERTIFICATE OF |
| AUTHORIZATION IS REQUIRED IN THE TITLE BLOCK OF EACH |
| SHEET. FAC 61G15-23.002(2) & FS 471.025. PLEASE SHOW |
| THE PRINTED NAME OF THE ENGINEERING SEALING THE |
| DOCUMENT AS WELL AS THE CA# ON EACH SHEET. |
| |
| 6. SHTS L1 THRU L4 SHALL BE SIGNED, SEALED WITH AN |
| EMBOSSED SEAL AND DATED AS REQUIRED IN SECTION 106.1. |
| ALSO THE FIRM LICENSE NUMBER IS REQUIRED IN THE TITLE |
| BLOCK. FAC 61G1-16.004(2)(5) & FS 481.2055. PLEASE |
| SIGN, SEAL & DATE EACH SHEET AND INDICATE THE FIRM |
| LICENSE NUMBER AS WELL. |
| |
| 7. SHT P0.1 WATER RISER DIAGRAM. THE WATER HAMMER |
| ARRESTORS SHALL BE LOCATED NEAR THE FIXTURE IN AN |
| "EFFECTIVE RANGE" NOT IN THE CEILING AS SHOWN. PDI-WH |
| 201 AND MANUF. INSTALLATION INSTRUCTIONS. PLEASE LOCATE |
| THE WHA'S AS REQUIRED. |
| |
| 8. SEPARATE IRRIGATION PLANS & PERMIT REQUIRED PRIOR TO |
| C.O. SECTION 106.3.5.1.3(9). |
| |
| REVIEW BY KEN STEVENS |
| (561) 805-6721 |
| FAX (561) 805-6731 |
| E-MAIL [email protected] |