2007-07-26 09:33:24 | BUILDING PLAN REVIEW |
| PERMIT: 07070734 |
| ADD: 480 HIBISCUS ST |
| CONT: LATITE ROOFING |
| TEL: (954)275-6024 |
| BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1STREVIEW |
| ACTION: DENIED |
| |
| 1)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT |
| ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 3) ALL PRODUCT APPROVALS ARE TO BE REVIEWED BY THE |
| DESIGN PROFESSIONAL, THESTRUCTURAL ENGINEER DEL LOS |
| REYES DOESN'T HAVE THEIR SHOP DRAWING STAMP INDICATING |
| THEIR REVIEW WITH APPROVAL; |
| WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE PRODUCT |
| WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED |
| AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR |
| TO SUBMITTAL |
| FOR JURISDICTIONAL APPROVAL. |
| |
| 4)PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION |
| AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE |
| FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE |
| SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. |
| PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTSTHE PRODUCT |
| IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT |
| HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR LOCAL |
| PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE 9B-72. |
| SEEWWW.FLORIDABUILDING.ORG |
| |
| 5)WEST WIND LABORATORY, INC, IS OFFERING ENGINEERING |
| SERVICES:471.023 F.S.CERTIFICATE OF AUTHORIZATION. |
| THE TITLE BLOCK FOR ANY SHEET BEARING THE NAME OF AN |
| ENGINEER PRACTICING UNDER A FICTITIOUS NAME, A |
| CORPORATION, OR A PARTNERSHIP, OFFERING ENGINEERING |
| SERVICES, SHALL INCLUDE THE CERTIFICATE OF |
| AUTHORIZATION NUMBER. |
| |
| 6) WEST WIND LABORATORY: PE JON RAGGETT: LICENSE IS |
| DELINQUENT, SEE ATTACHMENT. |
| |
| 7) P E JON RAGGETT PLANS, SPECIFICATIONS, REPORTS OR |
| OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND |
| BEING FILED FOR PUBLIC |
| RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN |
| PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| FL STATE STAT: 61G15-23.002 ENGINEERS |
| |
| 8) 61G15-23.00261G15-23.002 SEAL, SIGNATURE AND DATE |
| SHALL BE AFFIXED. |
| ACOVER OR INDEX SHEET FOR ENGINEERING SPECIFICATIONS |
| MAY BE USED AND THAT SHEET MUST BE SIGNED, SEALED AND |
| DATED BY THOSE PROFESSIONAL ENGINEERS IN RESPONSIBLE |
| CHARGE OF THE SPECIFICATIONS MAY BE USED AND THE |
| PREPERATION OF EACH SECTION OF THE ENGINEERING |
| SPECIFICATION WITH SUFFICIENT INFORMATION ON THE COVER |
| SHEET OR INDEX SO THAT THE USER WILL BE AWARE OF EACH |
| PORTION OF THESPECIFICATIONS FOR WHICH EACH |
| PROFESSIONAL ENGINEER IS RESPONSIBLE. |
| |
| 9) SHEET # 11 DOESN'T INDICATE WHO IS RESPONSIBLE FOR |
| THIS SHEET BUT THE PRESSURES DO NOT MATCH THE PRESSURES |
| PROVIDED BY PE DE LOS REYES SEE STRUCTURAL SHEET S-8.4 |
| AND THE PRESSURES FOR THE TYPICAL PENTHOUSESHOW |
| -137AT WALLS AND OVERHANGS. PLEASE TAKE NOTE OF |
| PRESSURES ON THIS SHEET!!!! THE SUPPLIED NOA |
| (04-0716.04) HAVE PRESSURES GOOD TO -101.0 AND SYSTEMS |
| LIMITATION # 1 INDICATES NO RATIONAL ANALYSIS OR |
| EXTRAPOLATION SHALL BE PERMITTED FOR ENHANCED |
| FASTENING. |
| |
| 10) JOHN MANSVILLE REPORT NOA (06-0626.05) INDICATE LOW |
| PRESSURES OF -75 PSF, WILL REQUIRE ENHANCED FASTENING |
| SEE LIMITATION# 7 ; |
| XX___ THE SYSTEM PROVIDED STATESLIMITATION# 7, |
| CALCULATIONS FROM RAS 117 SHALL BE SUBMITTED,THE |
| FASTENERRESISTANCE BE LESS THAN THATREQUIRED, AS |
| DETERMINED BY THEBUILDING OFFICIAL, A REVISED |
| FASTENER SPACING, PREPARED , SIGNED AND SEALED BY A |
| FLORIDA REGISTEREDPROFESSIONAL ENGINEER, REGISTERED |
| ARCHITECT OR REGISTERED ROOF CONSULTANT MAY BE |
| SUBMITTED. |
| |
| BUILDING PLAN REVIEW II |