2007-08-14 18:36:47 | 2004 FBC W/2007 REVISIONS | | INSTALL METAL PAN ROOF CARPORT | | | | DENIED BY BUILDING | | | | 1) SUBMIT THE PRODUCT APPROVAL FOR THE ROOF PANELS. THE | | SPAN AND LOAD TABLES, AS WELL AS, THE INSTALLATION | | INSTRUCTIONS ARE REQUIRED. | | | | 2) THE INFORMATION THAT WAS CIRCLED ON THE ENGINEERED | | BEAM SPAN TABLE ON SHEET 2 IS INCORRECT. | | | | 3)ANCHOR DETAIL #2, WHICH IS CIRCLED ON THE | | ENGINEERED DRAWINGS ON SHEET 3 IS FOR A 3 X 3 X .125 | | COLUMN AND THE LAYOUT DRAWINGS SPECIFY 4 X 4 COLUMNS. | | | | 4) SPECIFY THE FOOTING FOR THE 4 X 4 COLUMN CARRYING | | THE 2 X 5 BEAM. | | | | 5) RADON FEES IN THE AMOUNT OF $ 3.22 ARE OWED. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|