2007-08-07 13:02:48 | 2004 FBC WITH 2006 REVISIONS |
| REMODEL SFR AND CONVERT PORTION OF GARAGE TO CABANA |
| |
| DENIED BY BUILDING |
| |
| 1) IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY, PLANS STAMPED BY THEM AND |
| COPY OF RECEIPT SUBMITTED TO CITY OF |
| WEST PALM BEACH BUILDING DEPARTMENT, |
| BEFORE A BUILDING PERMIT CAN BE ISSUED. CHANGE OF USE |
| FROM GARAGE TO CABANA MAY REQUIRE PAYMENT IMPACT FEES |
| TO PALM BEACH COUNTY. |
| |
| 2) SPECIFY THE SCOPE OF WORK ON THE PLANS. SEE FBC |
| *106.1.1 OF THE CITY OF WPB AMENDMENTS TO THE 2004 |
| FBC. |
| |
| |
| 3) SPECIFY THE APPLICABLE BUILDING CODES AND DESIGN |
| DATA ON THE PLANS. SPECIFY WIND SPEED, EXPOSURE |
| CATEGORY, IMPORTANCE FACTOR, COMPONENT AND CLADDING |
| PRESSURES, ETC. SEE FBCR301.SPECIFY THE SCALE OF |
| THE DRAWINGS ON THE PLANS PER FBC* 106.1.2. |
| |
| 4) INDICATE ON THE PLANS THAT THE WINDOWS AND DOORS |
| ARE BEING REPLACED. NOTE: THIS IS NOT INDICATED ON THE |
| WORK DESCRIPTION ON THE PERMIT APPLICATION. |
| |
| 5) SPECIFY THE SIZES OF THE WINDOWS AND DOORS ON THE |
| PLANS. |
| |
| 6) THE STRUCTURAL WORK ON THIS PROJECT AT THE |
| CONVERSION OF THE EXISTING GARAGE TO COVERED PORCH AND |
| CABANA EXCEEDS THE PRESCRIPTIVE LIMITATIONS OF THE |
| CODE. THEREFORE, ENGINEERED DESIGN IS REQUIRED BY A |
| FLORIDA LICENSED DESIGN PROFESSIONAL. SEE R301.1.3 AND |
| FBC* 106.1. |
| |
| 7) SPECIFY THE REQUIRED BEARING CAPACITY OF THE SOIL |
| FOR THE DESIGN. SEE FBC* 106.1.2AND R 401.4.1. |
| |
| 8) SPECIFY HOW THE NEW WALL, COLUMNS AND BEAM AT THE |
| GARAGE WILL BE TIED INTO THE EXISTING WALL. FBC* |
| 106.1.2 |
| |
| 9) SPECIFY THE LIVE AND DEAD LOADS FOR THE FLOORS OF |
| THE REMODELED BATHROOMS AND THE FLAT AND SLOPED ROOFS |
| AT THE GARAGE. |
| |
| 10) PROVIDE A FLOOR PLAN OF THE EXISTING HOUSE AND |
| GARAGE. SHOW ALL EXISTING WALLS AND LABEL ALL ROOMS. |
| |
| 11) NO HANDWRITING IS ALLOWED ON THE PLANS. ALL CHANGES |
| TO THE PLANS ARE REQUIRED TO BE DATED AND INITIALED BY |
| THE DESIGNER OF RECORD. |
| |
| 12) THE NAME OF THE PERSON RESPONSIBLE FOR THE DESIGN |
| IS REQUIRED ON EACH SHEET ALONG WITH THEIR SIGNATURE. |
| FBC* 106.1 |
| |
| 13) PLEASE CLARIFY THE EXTENT OF STRUCTURAL WORK THAT |
| IS BEING DONE IN THE EXISTING BATHROOMS. |
| |
| 14) IN ORDER TO MAKE PLANS MORE CLEAR, INDICATE THE |
| LOCATION OF THE SECTION DETAILS ON THE FLOOR PLANS, |
| FOUNDATION PLANS OR ROOF PLANS WITH SECTION ID TAGS |
| (FOR EXAMPLE 1ON A4.)LABEL THE SECTION DETAIL |
| DRAWINGS WITH CORRESPONDING TAGS. FBC* 106.1.1 |
| |
| 15) SPECIFY HOW THE NEW BARREL TILEWILL BE ATTACHED |
| TO THE OVERHANG. SEE TILE NOA FOR OPTIONS. |
| |
| 16) SEE RED PENCIL NOTES ON THE PLANS REQUESTING |
| MISSING INFORMATION SUCH AS SPACING OF STUDS AT NEW |
| FRAME GARAGE WALL, EMBED DEPTH OF ANCHOR BOLTS, ETC. |
| |
| 17)SUBMIT MANUFACTURER'S SPECIFICATIONS AND LISTING |
| INFORMATION FOR THE BBQ THAT WILL ALLOW IT TO BE USED |
| UNDER A COMBUSTIBLE CEILING. |
| |
| 18) SUBMIT PRODUCT APPROVALS FOR THE ROOF COVERING |
| MATERIALS, GLASS BLOCK, SIMPSON CONNECTORS AND EXTERIOR |
| SWING PANEL DOOR AT THE GARAGE SHOWN ON A3. |
| |
| 19)WPB ADMIN CODE 106.3* PRODUCT |
| APPROVALS. THOSE PRODUCT WHICH ARE |
| REGULATED BY DCA RULE 9B-72 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| FOR JURISDICTIONAL APPROVAL. |
| |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |