Plan Review Notes
Plan Review Notes For Permit 07070447
Permit Number 07070447
Review Stop M
Sequence Number 2
Notes
Date Text
2007-09-19 15:01:48PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY THE
 PREPARER, SEE FBC 13-103.1.1.
  
 2) ENERGY CALCULATIONS LINE 15 IS TAKING CEILING FAN
 CREDIT, SEE FBC 13-607.2.A.3.1 CEILING FAN CREDIT MAY
 BE TAKEN IF ONE OR MORE CEILING FANS ARE INSTALLED IN
 EACH OF THE BEDROOMS AND A MINIMUM OF ONE CEILING FAN
 IS INSTALLED IN ALL PRIMARY LIVING AREAS (LIVING ROOMS,
 FAMILY ROOMS, OR GREAT ROOMS). PLEASE SHOW ON
 ELECTRICAL PLAN EXISTING CEILING FANS IN ALL REQUIRED
 ROOMS IF THEY EXIST OR REMOVE CREDIT FROM ENERGY
 CAL'S.
  
 3) I COULD NOT VERIFY THE A/C EQUIPMENT LISTED ON
 MECHANICAL PLAN WITH THE ARI DIRECTORY WEB-SITE TO
 CHECK SEER AND THAT IT IS A HEAT PUMP, PLEASE SUBMIT
 ARI LISTING AND DETAILED MANUFACTURER'S SPECIFICATION'S
 AND INSTALLATION INSTRUCTIONS FOR A/C SYSTEM.
  
 4) THE MECHANICAL PLAN SUBMITTED HAS TO MUCH FLOOR PLAN
 DETAIL ON IT AND IS DIFFICULT TO READ. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY. PER 2004 FBC
 106.1.1.
  
 5) THE DUCT DESIGN MUST BE PART OF THE PLAN AND CAN NOT
 BE ADDED BY HAND TO SOME OTHER PLAN, PLEASE SUBMIT A
 PROPER MECHANICAL PLAN.
  
 6) AN EXHAUST FAN IS REQUIRED IN THE MASTER BATHROOM
 TUB AND SHOWER AREA, SEE RES.R303.3.
  
 7) THE EXISTING BATHROOM REQUIRES A EXHAUST FAN , SEE
 RES. R303.3.
  
 8) PROVIDE FOR RETURN AIR TO THE EXISTING PART OF THE
 HOUSE IF THE FAMILY ROOM DOORS WERE CLOSED, SEE RES.
 M1602.4.
  
 9) MECHANICAL PLAN WILL NEED TO BE SIGNED AND SEALED BY
 THE ENGINEER AS HIS INFORMATION IS IN THE TITLE BLOCK,
 IF HIS INFORMATION WAS NOT IN THE TITLE BLOCK THEN IT
 WOULD NEED THE PREPARERS INFORMATION AND SIGNATURE, SEE
 WPB 106.1.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]
 .