Date |
Text |
2008-07-01 14:22:20 | |
| |
| |
| |
| THIS REVIEW WAS DONE UNDER THESE CURRENT CODE |
| CYCLES: |
| |
| THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 |
| RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1 |
| AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: |
| |
| 1} THERE WAS NOT A SHEET "A-1.5" IN THE PERMITTED SET |
| OF PLANS, THEREFORE THE PLAN SUBMITTED CANNOT BE A |
| REVISION. PLEASE SUBMIT THE CORRECT SHEET INTENDED TO |
| BE REVISED. |
| |
| 2} 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE |
| PERMITTED TO BE SUBMITTED WHEN APPROVED BY THE BUILDING |
| OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT |
| LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED |
| BY THE BUILDING OFFICIAL (SEE ALSO SECTION 106.3.5).* |
| THERE APPEARS TO BE SOME REVISIONS TO THE THE LIGHTS IN |
| THE DINING AND BAR AREA. IF THIS IS INTENDED AS PART OF |
| THE REVISION TO SHEETA-1.4, INDICATE THAT CHANGE ON THE |
| REVISION FORM.HAND DRAWN CHANGES TO THE PLAN ARE NOT |
| ACCEPTABLE FOR RECORD RETENTION OR CLARITY IN THE |
| FIELD. 106.1.3 FBC AS AMENDED. |
| |
| IF THERE ARE ANY QUESTIONS PLEASE CALL. |
| |
| BILL TROBAUGH |
| ELECTRICAL PLANS EXAMINER |
| CITY OF WEST PALM BEACH |
| 561/805-6718 |