Plan Review Notes For Permit 07070387 |
Permit Number |
07070387 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2007-07-31 10:20:37 | DENIED; | | 1. SEE ELECTRICAL PLAN REVIEW'S NOTE # 2. | | 2. GENERAL PLUMBING NOTE # 16, SHOW UL LISTING FOR FIRE | | ASSEMBY TO BE USED AND THE MANUFACTURE OF PRODUCT. | | 3. SANITARY RISER AND FLAT DRAWING NOT TO CODE; | | A) BREAK SINK NOT PERMITED TO GO THRU A | | BATHROOM GROUP. SECTION 909.1 | | B) SHOWER IS NOT VENTED. | | 4. SHOW TYPE OF THERMAL EXPANSION TO BE USED FOR THE | | HOT WATER. SECTION 607.3. | | 5. THE PRIVATE BATHROOM DOES NOT COMPLY WITH, FBC-2004 | | BUILDING CHAPTER 11 SECTION 11-4.1.3(11) I.E. " A | | PRIVATE TOILET ROOM FOR THEOCCUPENT OF A PRIVATE | | OFFICE". THIS BATHROOM SHALL BE ADAPTABLE WITH ALL | | BACKING REQUIRED AND TOILET AT 18" OFF SIDE WALL. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|