Plan Review Notes
Plan Review Notes For Permit 07070269
Permit Number 07070269
Review Stop P
Sequence Number 1
Notes
Date Text
2007-09-01 07:04:00DENIED
 REFERENCE: FBC-2004
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. ALL SHEETS, THE ADDRESS FOR THE ARCHITECT IN THE
 TITLE BLOCK DOES NOT REFLECT THE ADDRESS OF RECORD ON
 THE FLORIDA STATE DBPR WEBSITE. (SEE ATTACHED SHEET).
 PRIOR TO RESUBMITTING, PLEASE UPDATE THE DBPR WEBSITE
 OR THE TITLE BLOCKS SO THAT THE ADDRESS IN THE TITLE
 BLOCK REFLECTS THE ADDRESS ON THE DBPR WEBSITE. FAC
 61G1-16.004(1) & FS 481.2055.
  
 2. SHT A6 THE SANITARY ISOMETRIC RISER DIAGRAM DOES NOT
 REFLECT THE FLOOR PLAN, NOR DOES IT MEET CODE
 REQUIREMENTS. SECTION 106.1.1. THE WASH MACHINE AND LAV
 FOR THE POWDER ROOM LOCATION ARE NOT REFLECTIVE OF THE
 FLOOR PLAN. THE BATHROOMS ON THE SECOND FLOOR DO NOT
 REFLECT THE LOCATIONS INDICATED ON THE FLOOR PLAN. THE
 LAV IN ONE BATHROOM IS INDICATED AS A WHR AND THE
 SHOWER IS INDICATED AS A TUB. THE WASH MACHINE SHALL
 SHOW THE CLEANOUT AT 4FT ABOVE THE FLOOR FOR ACCESS AND
 REQUIRES A STANDPIPE A MINIMUM 18".SECTIONS 708.9,
 802.4 & 1002.1. THE KITCHEN SINK SHALL DISCHARGE
 DOWNSTREAM OF THE WET VENT FOR THE POWDER ROOM. SECTION
 909.1.--SEE RED LINE EXAMPLE FOR PLAN VIEW LAYOUT
 OF FIXTURES AND PIPING THAT REFLECTS THE FLOOR PLAN.
 PLEASE HAVE ISOMETRIC RISER DIAGRAM REFLECT THE FLOOR
 PLAN AND MEET ALL CODE REQUIREMENTS. SECTION
 106.3.5.4(9).
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL
 VOID SHEETS FROM ALL PLANS AND PLACE ONE SET
 OF THEM LOOSELY ON TOP OF THE COLLATED PLANS
 TO BE REVIEWED. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]