Date |
Text |
2007-08-30 14:27:29 | |
| |
| DENIED |
| |
| THIS REVIEW IS BASED PERMIT APPLICATIONS FOR FEE SIMPLE |
| TOWNHOUSES |
| |
| 1)PLEASE SET UP MEETING WITH THE PLANNING AND ZONING |
| DEPARTMENT FOR SEPARATION OF PROPERTY AND WITH |
| ADDRESSING TO ARRANGE SEPARATE ADDRESSES FOR EACH |
| PROPERTY |
| |
| 2)THREE SEPARATE AND COMPLETE PERMIT APPLICATIONS ARE |
| REQUIRED FOR EACH TOWNHOUSE, EACH SHALL CONTAIN THE |
| INDIVIDUAL ADDRESS FOR THE UNIT AND ALL PERTINENT |
| INFORMATION ( NOTICE OF COMMENCEMENT, PRODUCT |
| APPROVALS, ENERGY CALC'S, ETC.) |
| |
| 3)THE CLAIMED VALUATION ON THE PERMIT |
| APPLICATION IS LOW. FOR PERMITTING PURPOSES, VALUATION |
| OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT |
| COST EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS |
| ICC (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS |
| SERVICES PER 108.3 FBC* |
| ********VALUE FOR EACH UNIT BASED ON THE BVD FROM THE |
| ICC AT THE TIME OF PERMIT APPLICATION IS $186,546.00 |
| PER UNIT****** |
| |
| 4)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| ADDED TO THE PERMIT APPLICATION FEES. THE FEES ARE DUE |
| ON EACH UNIT BASED ON 1,943 SQ. FT. |
| |
| 5)DUE TO PERMIT EXPIRATION AND RE-APPLICATION THE |
| DESIGN DATA AND GENERAL INFORMATION SHALL COMPLY WITH |
| THE 2004 FBC W/ 2006 AMENDMENTS |
| |
| 6)FASTENER SCHEDULE TO COMPLY WITH THE NEW REVISION |
| TO THE 2004 FBC RES. R803.2.3.1 REQUIRES 8D RING SHANK |
| NAILS AT 6" O/C EDGES AND FIELD AND 4" O/C EDGES AND |
| FIELD IN ZONE 3 |
| |
| 7)THE FIRE RATED SYSTEM CHOSEN ON A8 NO 8-2-11W FROM |
| RINKER SHOWS BLOCK FURRED WITH METAL CHANNEL AND 1/2" |
| DRYWALL APPLIED TO BOTH SIDES, THIS DETAIL MUST |
| CONTINUE FROM FLOOR TO UNDERSIDE OF ROOF DECK (PLYWOOD |
| SHEATHING) PLEASE NOTE THAT THE SYSTEM SEEMS TO STOP AT |
| BOTTOM OF TRUSSES ON SECTION L/8. |
| |
| 8)PLEASE SEE THAT SECTION L/8 IS VERY CONFUSING IT |
| SHOWS STUCCO, 2X2 FURRING AND 1-5/8" METAL STUDS. IT |
| SHOULD SHOW THE FIRE RATING DETAIL AND THE CHOSEN |
| FURRING DETAIL FOR ELECTRICAL/PLUMBING TO KEEP THE FIRE |
| RATING INTACT. |
| |
| 9)THE WINDOWS PROVIDED FOR THE MASTER BEDROOM SH34 DO |
| NOT MEET THE MINIMUM REQUIRED VERTICAL OPENING OF 24" |
| PER R310.1.2 FBC RES. |
| |
| 10)THE SHUTTER PRODUCT APPROVAL IS NO LONGER VALID, A |
| NEW DRAWING # 06-368 UNDER FL# 7030 SEEMS TO BE THE |
| SAME PANEL TYPE WITH CHANGES ONLY FOR THE UPDATED ASCE |
| 7-02. ALSO THE SHUTTER SCHEDULE WILL BE NEED TO BE |
| SEPARATED INTO THE INDIVIDUAL UNITS FOR EACH PERMIT. |
| |
| 11)THE ROOFING PRODUCT APPROVAL IS ALSO UPDATED FL# |
| 183-R2 WITH A NEW MIAMI-DADE REPORT # 05-1115.11 |
| |
| 12)THE SIMONTON WINDOW PRODUCT APPROVAL FOR THE |
| 500-500 STORMBREAKER SLIDING GLASS DOOR IS NO LONGER |
| APPROVED ON THE STATE SITE AND THE MIAMI-DADE FILE HAS |
| BEEN CLOSED. |
| |
| 13)A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT IS REQUIRED PRIOR TO |
| A PERMIT BEING ISSUED |
| |