Plan Review Notes For Permit 07070098 |
Permit Number |
07070098 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2007-08-21 07:19:30 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)YOU'VE DESIGNED THIS JOB TO -47.2 PSF.ENGINEER | | HAS SPECIFIED DESIGN PRESSURE OF -51.6.YOU HAVE | | CHANGED THE DESIGN PRESSURE ON THE INSTALLATION | | SCHEDULE BUT DID NOT CHANGE THE ANCHOR SPACING, SEE | | SHEET 7 OF THE PRODUCT APPROVAL. | | | | 2.)PLEASE SEE THE NOTE AT THE BOTTOM OF THE | | INSTALLATION SCHEDULE - "ANCHOR TYPE MUST BE SPECIFIC, | | EG. THERE ARE DIFFERENT TYPES OF TAPCONS WITH DIFFERENT | | STRENGTH VALUES."THE INSTALLATION SCHEDULE STATES | | "1/4" TAPCON".THERE ARE TWO DIFFERENT 1/4" TAPCONS ON | | THE ANCHOR SCHEDULE.IN THIS CASE, IT APPEARS THAT YOU | | ARE SPECIFYING ANCHORING FOR THE MORE STRINGENT.IF | | THIS IS NOT THE CASE, SPECIFIC ANCHOR TYPE WILL BE | | REQUIRED ON THE INSTALLATION SCHEDULE. | | |
|