Plan Review Notes
Plan Review Notes For Permit 07070038
Permit Number 07070038
Review Stop B
Sequence Number 1
Notes
Date Text
2007-07-09 16:44:44PROJECT: 3705 SOUTH FLAGLER DRIVE
  
 PROJECT DETAIL: REMOVE AND REPLACE SOFFITS AT 3RD
 FLOOR.
  
 REVIEW: 2004 FLORIDA BUIDING AND EXISTING BUILDING CODE
 WITH 2006 REVISIONS.
  
 STATUS: DENIED
  
  
 COMMENTS:
  
  
 1) REQUIRE A NOTICE OF COMMENCEMENT AS PER THE
 FOLLOWING:
  
 FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
  
 2) SECTION 2504
 VERTICAL AND HORIZONTAL ASSEMBLIES
 2504.1 SCOPE.
 THE FOLLOWING REQUIREMENTS SHALL BE MET WHERE
 CONSTRUCTION INVOLVES GYPSUM BOARD, LATH AND PLASTER IN
 VERTICAL AND HORIZONTAL ASSEMBLIES.
  
 2504.1.1 WOOD FRAMING.
 WOOD SUPPORTS FOR LATH OR GYPSUM BOARD, AS WELL AS WOOD
 STRIPPING OR FURRING, SHALL NOT BE LESS THAN 2 INCHES
 (51 MM) NOMINAL THICKNESS IN THE LEAST DIMENSION.
 EXCEPTION: THE MINIMUM NOMINAL DIMENSION OF WOOD
 FURRING STRIPS INSTALLED OVER SOLID BACKING SHALL NOT
 BE LESS THAN 1 INCH BY 2 INCHES (25 MM BY 51 MM).
  
 2504.1.2 STUDLESS PARTITIONS.
 THE MINIMUM THICKNESS OF VERTICALLY ERECTED STUDLESS
 SOLID PLASTER PARTITIONS OF 3/8-INCH (9.5 MM) AND
 ?-INCH (19.1 MM) RIB METAL LATH OR ?-INCH-THICK (12.7
 MM) LONG-LENGTH GYPSUM LATH AND GYPSUM BOARD PARTITIONS
 SHALL BE 2 INCHES (51 MM).
  
 3) ALL MATERIAL TO COMPLY WITH THE FOLLOWING:
  
 SECTION 2507
 LATHING AND PLASTERING
 2507.1 GENERAL.
 LATHING AND PLASTERING MATERIALS AND ACCESSORIES SHALL
 BE MARKED BY THE MANUFACTURER?S DESIGNATION TO INDICATE
 COMPLIANCE WITH THE APPROPRIATE STANDARDS REFERENCED IN
 THIS SECTION AND STORED IN SUCH A MANNER TO PROTECT
 THEM FROM THE WEATHER.
 2507.2 STANDARDS.
 LATHING AND PLASTERING MATERIALS SHALL CONFORM TO THE
 STANDARDS LISTED IN TABLE 2507.2 AND CHAPTER 35 AND,
 WHERE REQUIRED FOR FIRE PROTECTION, SHALL ALSO CONFORM
 TO THE PROVISIONS OF CHAPTER 7.
 TABLE 2507.2
 LATH, PLASTERING MATERIALS AND ACCESSORIES
  
 MATERIAL STANDARD
 ACCESSORIES FOR GYPSUM VENEER BASE ASTM C 1047
 EXTERIOR PLASTER BONDING COMPOUNDS ASTM C 932 GYPSUM
 BASE FOR VENEER PLASTERS ASTM C 588 GYPSUM CASTING
 AND MOLDING PLASTER ASTM C 59 GYPSUM KEENE?S CEMENT
  ASTM C 61
 GYPSUM LATH ASTM C 37
 GYPSUM PLASTER ASTM C 28
 GYPSUM VENEER PLASTER ASTM C 587
 INTERIOR BONDING COMPOUNDS, GYPSUM ASTM C 631 LIME
 PLASTERS ASTM C 5; C 206
 MASONRY CEMENT ASTM C 91
 METAL LATH ASTM C 847
 PLASTER AGGREGATES
 SAND
  
 PERLITE
 VERMICULITE
 ASTM C 35;
 C 897
 ASTM C 35
 ASTM C 35
 PLASTIC CEMENT ASTM C 1328
 BLENDED CEMENT ASTM C 595
 PORTLAND CEMENT ASTM C 150
 STEEL STUDS AND TRACK ASTM C 645; C 955
 STEEL SCREWS ASTM C 1002; C 954
 WELDED WIRE LATH ASTM C 933
 WOVEN WIRE PLASTER BASE ASTM C 1032
  
 4) PLEASE SUBMIT 2 COPIES OF A BUILDING PLOT PLAN
 INDICATING WHERE SOFFIT REPAIRS ARE TO BE MADE.
  
  
 5) SAFEGUARDS DURING CONSTRUCTION MUST BE MAINTAINED AS
 FOLLOWS:
  
 SECTION 1302
 CONSTRUCTION SAFEGUARDS
 1302.1REMODELING AND ADDITIONS.
 REQUIRED EXITS, EXISTING STRUCTURAL ELEMENTS, FIRE
 PROTECTION DEVICES AND SANITARY SAFEGUARDS SHALL BE
 MAINTAINED AT ALL TIMES DURING REMODELING, ALTERATIONS,
 REPAIRS OR ADDITIONS TO ANY BUILDING OR STRUCTURE.
 EXCEPTIONS:
 1. WHEN SUCH REQUIRED ELEMENTS OR DEVICES ARE BEING
 REMODELED, ALTERED OR REPAIRED, ADEQUATE SUBSTITUTE
 PROVISIONS SHALL BE MADE.
 2. WHEN THE EXISTING BUILDING IS NOT OCCUPIED. 1302.2
 MANNER OF REMOVAL.
 WASTE MATERIALS SHALL BE REMOVED IN A MANNER WHICH
 PREVENTS INJURY OR DAMAGE TO PERSONS, ADJOINING
 PROPERTIES AND PUBLIC RIGHTS-OF-WAY.
  
 PLAN REVIEW: KEN CONRAD
 PHONE: 561.805.6666
 E-MAIL: [email protected]