2007-08-29 14:57:44 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & |
| REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST |
| PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA |
| ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS). |
| |
| *** DENIED *** |
| 1) ENERGY CALCULATIONS LINE 15 IS TAKING THE CEILING |
| FAN CREDIT. THE ELECTRICAL PLANS NEED TO SHOW CEILING |
| FANS (NOT CEILING FIXTURES) IN THE REQUIRED ROOMS. |
| ** 2004 FBC 13-607.2.A.3.1 CEILING FANS.CEILING FAN |
| CREDIT MAY BE TAKEN IF ONE OR MORE CEILING FANS ARE |
| INSTALLED IN EACH OF THE BEDROOMS AND A MINIMUM OF ONE |
| CEILING FAN IS INSTALLED IN ALL PRIMARY LIVING AREAS |
| (LIVING ROOMS, FAMILY ROOMS, OR GREAT ROOMS). |
| PRESCRIPTIVE REQUIREMENTS IN SECTION 13-607.1.A.1 SHALL |
| BE MET. |
| ** 13-607.1.A.1 CEILING FAN CREDIT.HOUSES FOR WHICH |
| CEILING FAN CREDIT IS CLAIMED IN ACCORDANCE WITH THE |
| CRITERIA OF SECTION 13-607.2.A.3.1 SHALL HAVE CEILING |
| FANS INSTALLED WITH MINIMUM FAN BLADE DIAMETERS OF NO |
| LESS THAN THOSE LISTED IN TABLE 13-607.1A.1 FOR THE |
| SIZE AND SHAPE OF THE ROOM. |
| |
| 2) ONLY ONE COPY OF THE ENERGY CALCULATIONS AND COOLING |
| LOAD CALCULATIONS WERE SUBMITTED. TWO COPIES NEED TO BE |
| SUBMITTED, PLEASE CORRECT. |
| |