Plan Review Notes
Plan Review Notes For Permit 07060690
Permit Number 07060690
Review Stop B
Sequence Number 1
Notes
Date Text
2007-07-24 18:28:25PROJECT: 5301 SOUTH DIXIE HIGHWAY
  
 PROJECT DESCRIPTION: STRUCTURAL REINFORCEMENT OF
 EXISTING STRUCTURAL FRAMING
  
 CODE REVIEW:2004 FLORIDA EXISTING BUILDING CODE
 W/2006 REVISIONS
 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONSCITY OF
 WEST PALM BEACH/ FLORIDA BUILDING CODE/ADMINISTRATION
 AMENDMENTS, CHAPTER 1, 2004 EDITION
  
 STATUS: DENIED
  
  
 COMMENTS:
  
  
 1) REQUIRE A NOTICE OF COMMENCEMENT AS PER THE
 FOLLOWING:
  
 FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
  
 2) PLEASE DESIGNATE LEVEL OF ALTERATION AS PER THE
 FOLLOWING:
  
 301.5
 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR A
 COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
  
 3) INDICATE OCCUPANCY AND USE:
  
 301.4OCCUPANCY AND USE.
 WHEN DETERMINING THE APPROPRIATE APPLICATION OF THE
 REFERENCED SECTIONS OF THIS CODE, THE OCCUPANCY AND USE
 OF A BUILDING SHALL BE DETERMINED IN ACCORDANCE WITH
 CHAPTER 3 OF THEFLORIDA BUILDING CODE,
 BUILDING.
  
 4) AS PER THE EXISTING BUILDING CODE, THE FOLLOWING
 SHALL APPLY:
  
 407.3.1NEW STRUCTURAL FRAME MEMBERS.
 NEW STRUCTURAL FRAME MEMBERS USED IN THE REPAIR OF
 DAMAGED BUILDINGS, INCLUDING ANCHORAGE AND CONNECTIONS,
 SHALL COMPLY WITH THE FLORIDA BUILDING CODE, BUILDING.
  
 5) PLEASE COMPLY WITH THE FOLLOWING:
  
 2101.3 CONSTRUCTION DOCUMENTS.
 THE CONSTRUCTION DOCUMENTS SHALL SHOW ALL OF THE
 ITEMS REQUIRED BY THIS CODE INCLUDING THE FOLLOWING:
 1.SPECIFIED SIZE, GRADE, TYPE AND LOCATION OF
 REINFORCEMENT, ANCHORS AND WALL TIES.
  
 6) PLEASE SUBMIT A ROOF FRAMING PLAN. INDICATE THE
 CONTINUOUS LATERAL BRACING:
  
 2319.17.2.1.8
 ALL TRUSSES SHALL BE PROPERLY BRACED TO ACT AS A
 SYSTEM. SUCH BRACING SHALL BE INCLUDED AS PART OF THE
 DESIGN DOCUMENT.
  
 7)PLEASE SHOW THE BUILDING ELEVATIONS AND INDICATE
 THE ROOF PITCH.
  
 8)INDICATE SPECIES AND GRADE OF NEW STRUCTURAL LUMBER
 TO BE USED.
  
 9)PLEASE SPECIFY GRADE AND LENGTH OF ANCHOR BOLTS.
  
 10) PLEASE SHOW THE DIMENSIONS OF THE EXISTING
 FOUNDATION PADS.
  
 11) PLEASE SUBMIT STRUCTURAL CALCULATIONS.
  
 12) SUBMIT EPOXY SPECIFICATIONS.
  
 13) PLEASE PROVIDE GROUT AND MORTAR SPECIFICATIONS.
  
 14) SHOW ALL ACCESSIBILITY DIMENSIONS FOR THE BATHROOMS
 TO BE ADDED.
  
 15) THE INDICATED CONSTRUCTION VALUATION APPEARS TO BE
 LOW. PLEASE PROVIDE SUPPORTING DATA.
  
  
 PLAN REVIEW: KEN CONRAD
 PHONE: 561.805.6666
 E-MAIL: [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved