2007-08-08 08:42:31 | 2004 FLORIDA BUILDING CODE WITH 2006 AMENDMENTS |
| UNPERMITTED ADDITION TO SINGLE FAMILY DWELLING |
| CONNECTED EXISTING DETACHED GARAGE TO EXISTING DWELLING |
| AND CONVERTED TO LIVING SPACE |
| WOOD FRAME AND STUCCO CONSTRUCTION |
| |
| DENIED BY BUILDING |
| |
| 1) FBC EXISTING BUILDING 901.1 SCOPE. |
| AN ADDITION TO A BUILDING OR STRUCTURE SHALL COMPLY |
| WITH THE BUILDING, PLUMBING, ELECTRICAL, AND MECHANICAL |
| CODES, WITHOUT REQUIRING THE EXISTING BUILDING OR |
| STRUCTURE TO COMPLY WITH ANY REQUIREMENTS OF THOSE |
| CODES OR OF THESE PROVISIONS. |
| |
| 2) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT |
| MUST BE SUBMITTED BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| 3)IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY, PLANS STAMPED BY THEM AND |
| COPY OF RECEIPT SUBMITTED TO CITY OF |
| WEST PALM BEACH BUILDING DEPARTMENT, |
| BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| |
| 4) THE VALUE OF THE WORK FOR THE ADDITION HAS BEEN |
| INCREASED TO $ 66312.00BASED ON ICC BUILDING |
| VALUATION DATA. ADDITIONAL PERMIT FEES AND RADON FEES |
| OF $1130.81 ARE DUE. |
| |
| 5) TWO SETS OF SIGNED AND SEALED PLANS ARE REQUIRED. |
| SOME OF THE DRAWINGS DO NOT HAVE THE EMBOSSED SEAL AND |
| SOME HAVE THE ENGINEER'S TITLE BLOCK BUT ARE NOT SIGNED |
| AND SEALED. |
| SEE FS 471 AND FAC 61G15-23.002. |
| |
| 6)SIGNED AND SEALED PLANS CAN NOT BE ALTERED USING |
| WHITEOUT. HANDWRITTENCHANGES TO SIGNED AND SEALED |
| PLANS MUST BE MADE BY THE DESIGNER OF RECORD (DOR) AND |
| ARE REQUIRED TO BE SIGNED AND DATED. SEE FS 471. |
| |
| 7) SUBMIT ENERGY CALCULATIONS FOR THE ADDED LIVING |
| SPACE AS REQUIRED BY 2004 FBC CHAPTER 13. |
| |
| 8) SPECIFY THE R-VALUES FOR THE WALL AND CEILING |
| INSULATION ON THE PLANS. |
| |
| 9)SHOW COMPLIANCE WITH THE FOLLOWING: |
| R313.1 SMOKE ALARMS . |
| SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING |
| LOCATIONS: |
| 1.IN EACH SLEEPING ROOM. |
| 2.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE |
| IMMEDIATE VICINITY OF THE BEDROOMS. |
| 3.ON EACH ADDITIONAL STORY OF THE DWELLING, |
| INCLUDING BASEMENTS BUT NOT INCLUDING CRAWL SPACES AND |
| UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS |
| WITH SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR |
| BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON |
| THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER |
| LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE |
| FULL STORY BELOW THE UPPER LEVEL. |
| WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE |
| INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM |
| DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT |
| THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE |
| ALARMS IN THE INDIVIDUAL UNIT. THE ALARM SHALL BE |
| CLEARLY AUDIBLE IN ALL BEDROOMS OVER BACKGROUND NOISE |
| LEVELS WITH ALL INTERVENING DOORS CLOSED. |
| ALL SMOKE ALARMS SHALL BE LISTED AND INSTALLED IN |
| ACCORDANCE WITH THE PROVISIONS OF THIS CODE AND THE |
| HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA |
| 72. |
| |
| |
| R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. |
| WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS |
| REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING |
| ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE |
| INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE |
| ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE |
| ALARMS SHALL BE INTERCONNECTED AND HARD WIRED. |
| EXCEPTIONS: |
| 1. SMOKE ALARMS IN EXISTING AREAS SHALL NOT BE |
| REQUIRED TO BE INTERCONNECTED AND HARD WIRED WHERE THE |
| ALTERATIONS OR REPAIRS DO NOT RESULT IN THE REMOVAL OF |
| INTERIOR WALL OR CEILING FINISHES EXPOSING THE |
| STRUCTURE, UNLESS THERE IS AN ATTIC, CRAWL SPACE, OR |
| BASEMENT AVAILABLE WHICH COULD PROVIDE ACCESS FOR HARD |
| WIRING AND INTERCONNECTION WITHOUT THE REMOVAL OF |
| INTERIOR FINISHES. |
| 2.REPAIRS TO THE EXTERIOR SURFACES OF DWELLINGS |
| ARE EXEMPT FROM THE REQUIREMENTS OF THIS SECTION. |
| |
| 10) SUBMIT TWO COPIES OF A SURVEY AND A SITE PLAN |
| SHOWING THE LOCATION OF THE ADDITION AND DISTANCE TO |
| PROPERTY LINES. |
| |
| 11) SHOW COMPLIANCE WITH R302.1 EXTERIOR WALLS. |
| EXTERIOR WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM) |
| SHALL HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE |
| RATING WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL |
| NOT EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM |
| AN ADJACENT PROJECTION OR WALL. |
| EXCEPTION : DETACHED GARAGES ACCESSORY TO A DWELLING |
| LOCATED WITHIN 2 FEET (610 MM) OF A LOT LINE SHALL BE |
| PERMITTED TO HAVE ROOF EAVE PROJECTIONS NOT EXCEEDING 4 |
| INCHES (102 MM). |
| PROJECTIONS EXTENDING INTO THE 6-FOOT (1829 MM) |
| SEPARATION DISTANCE SHALL HAVE NOT LESS THAN 1-HOUR |
| FIRE-RESISTIVE CONSTRUCTION ON THE UNDERSIDE. THE ABOVE |
| PROVISIONS SHALL NOT APPLY TO WALLS WHICH ARE |
| PERPENDICULAR TO A LINE EXTENDING FROM THE POINT FROM |
| WHICH THE SEPARATION DISTANCE HAS BEEN MEASURED RUNNING |
| AND PARALLEL TO THE PROPERTY LINE. |
| EXCEPTION: TOOL AND STORAGE SHEDS, PLAYHOUSES AND |
| SIMILAR STRUCTURES ARE NOT REQUIRED TO PROVIDE WALL |
| PROTECTION BASED ON LOCATION ON THE LOT. |
| |
| 12) SPECIFY THE REQUIRED SOIL BEARING CAPACITY FOR THE |
| DESIGN ON THE PLANS. |
| |
| 13)PROVIDE A FOUNDATION PLAN FOR THE ADDITION, WHICH |
| SPECIFIES THE FOOTING DIMENSIONS, REINFORCING DISTANCE |
| BELOW AND ABOVE GRADE. SEE FBC R403.1 AND R404.4.6 ALSO |
| SHOW THAT THE CONCRETE SLAB COMPLIES WITHR506 FOR |
| SLABS AND R320.1 FOR TERMITE TREATMENT. |
| |
| 14) SHOW COMPLIANCE WITH R403.1.4 MINIMUM DEPTH. ALL |
| EXTERIOR FOOTINGS SHALL BE PLACED AT LEAST 12 INCHES |
| (305 MM) BELOW THE UNDISTURBED GROUND SURFACE. |
| |
| 15) SHOW COMPLIANCE WITH R704 WHICH REQUIRES A |
| CLEARANCE OF 6" BETWEEN EXTERIOR WALL COVERINGS AND |
| FINAL EARTH GRADE FOR INSPECTION FOR TERMITE |
| INSPECTION. |
| |
| 16)SHOW COMPLIANCE WITH R319.1 LOCATION REQUIRED. IN |
| AREAS SUBJECT TO DECAY DAMAGE AS ESTABLISHED BY TABLE |
| R301.2(1) , THE FOLLOWING LOCATIONS SHALL REQUIRE THE |
| USE OF AN APPROVED SPECIES AND GRADE OF LUMBER, |
| PRESSURE TREATED IN ACCORDANCE WITH AWPA C1, C2, C3, |
| C4, C9, C15, C18, C22, C23, C24, C28, C31, C33, P1, P2 |
| AND P3, OR DECAY-RESISTANT HEARTWOOD OF REDWOOD, BLACK |
| LOCUST, OR CEDARS. 5. WOOD SIDING, SHEATHING AND WALL |
| FRAMING ON THE EXTERIOR OF A BUILDING HAVING A |
| CLEARANCE OF LESS THAN 6 INCHES (152 MM) FROM THE |
| GROUND. |
| |
| 17) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED |
| GRADE. |
| CONCRETE AND MASONRY FOUNDATION WALLS SHALL EXTEND |
| ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT |
| ALL POINTS A MINIMUM OF 4 INCHES (102 MM) WHERE MASONRY |
| VENEER IS USED AND A MINIMUM OF 6 INCHES (152 MM) |
| ELSEWHERE. |
| |
| |
| 18) SHOW COMPLIANCE WITH R301.1 DESIGN. |
| BUILDINGS AND STRUCTURES, AND ALL PARTS THEREOF, SHALL |
| BE CONSTRUCTED TO SAFELY SUPPORT ALL LOADS, INCLUDING |
| DEAD LOADS, LIVE LOADS, ROOF LOADS, FLOOD LOADS AND |
| WIND LOADS AS PRESCRIBED BY THIS CODE. THE CONSTRUCTION |
| OF BUILDINGS AND STRUCTURES SHALL RESULT IN A SYSTEM |
| THAT PROVIDES A COMPLETE LOAD PATH CAPABLE OF |
| TRANSFERRING ALL LOADS FROM THEIR POINT OF ORIGIN |
| THROUGH THE LOAD -RESISTING ELEMENTS TO THE FOUNDATION. |
| PROVIDE DETAILS THAT SPECIFY THE CONNECTIONS USED TO |
| COMPLY. |
| |
| 19 PROVIDE A TYPICAL WINDOW OPENING DETAIL INDICATING |
| THE FRAMING, HEADER, CONNECTORS, SUBSTRATE FOR STORM |
| PANEL ANCHORS, ETC. |
| |
| 20) THE FLOOR PLAN SHOWS AN INTERIOR WALL INTERSECTING |
| THE EXTERIOR FRONT WALL AT A WINDOW. PLEASE CORRECT. |
| |
| 21) BATHROOM WINDOWS ARE REQUIRED TO BE SAFETY GLAZING |
| PER R803.1. |
| |
| 22) SPECIFY THE EXTERIOR COVERING AT THE OVERHANGS. |
| |
| 23) SHOW COMPLIANCE WITHR806.1 VENTILATION REQUIRED. |
| |
| ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE |
| CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF |
| RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE |
| SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE |
| ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE |
| PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WIT H 1 / |
| 8 INCH (3.2 MM) MINIMUM TO ? INCH (6.4 MM) MAXIMUM |
| OPENINGS. ALSO SEE R806.2. |
| |
| 24) R803.2.3.1 REQUIRES RING SHANK NAILS TO BE USED FOR |
| ALL ROOF ZONES. REVISE ROOF SHEATHING FASTENING |
| SCHEDULE ON A4. |
| |
| 25) UPDATE THE REFERENCE TO ASCE7-98ON SHEET 4 TO |
| ASCE7-02 TO COMPLY WITH THE 2004 FBC. |
| |
| 26) SPECIFY THE CONNECTORS FOR THE ROOF TRUSSES ON THE |
| PLANS. |
| |
| 27) SUBMIT PRODUCT APPROVALS FOR THE EXTERIOR IN SWING |
| DOOR, THE SINGLE HUNG WINDOWS, WINDOW MULLIONS, SLIDING |
| GLASS DOORS, ROOF MATERIAL, STORM PANELS. |
| |
| 28) SUBMIT A KEY PLAN AND INSTALLATION SCHEDULE FOR THE |
| STORM PANELS. SPECIFY THE MOUNT TYPE, THE ANCHOR TYPE, |
| THE ANCHOR SPACING, EDGE DISTANCE, SPANS, ETC. |
| |
| 29)PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. |
| |
| 30)WPB ADMIN CODE 106.3* PRODUCT |
| APPROVALS. THOSE PRODUCT WHICH ARE |
| REGULATED BY DCA RULE 9B-72 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| FOR JURISDICTIONAL APPROVAL. |
| |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |