Date |
Text |
2007-06-22 13:37:50 | ***FAILED*** |
| |
| |
| 1)SETBACKS ARE INSUFFICIENT.MEASURED FROM WATER'S |
| EDGE, THERE MUST BE A 5' SETBACK TO BOTH THE SIDES AND |
| THE REAR PROPERTY LINE.ALSO, PLEASE INDICATE DISTANCE |
| FRO PRINCIPAL STRUCTURE TO WATER'S EDGE (MUST BE A |
| MINIMUM OF 4'). |
| |
| 2)AS THE SURVEY DOES NOT SHOW AN EXISTING FENCE |
| SURROUNDING THE POOL, A FENCE PERMIT SHALL BE SUBMITTED |
| CONCURRENTLY AND SHALL CONFORM TO THE MINIMUM STANDARDS |
| PROVIDED BELOW. |
| |
| AS PER THE CITY OF WEST PALM BEACH ZONING AND LAND |
| DEVELOPMENT REGULATIONS, SECTION 94-304(D)(2)(B)+(C): |
| |
| B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE |
| OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT |
| ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF |
| THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. |
| BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN |
| HEIGHT ABOVE GRADE. |
| C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE |
| THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND |
| SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR |
| WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF |
| GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL |
| SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH |
| WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT |
| SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A |
| 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, |
| AT THE PROPERTY LINE, TO ENSURE PRIVACY. |
| |
| |
| CHRIS HOOPS |
| ZONING TECHNICIAN |
| 561-805-6720 |