2007-07-11 17:57:38 
  
 DENIED
  
 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES. NOTE FEES ARE DUE
 IN THE AMOUNT OF $ 1.44 FOR STATE OF FLORIDA RADON FEE
  
 3)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE
 SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES.
 ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG
  
 4) THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER
 SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED
  
 5)NO PRODUCT APPROVALS WERE SUBMITTED FOR ROOF
 MEMBRANE, AND CONSTRUCTION STRAPS/TIES
  
 6)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 7)ALTHOUGH THE DRAWINGS SHOW THE MINIMUM DEPTH OF
 FOUNDATION ON THE WALL SECTIONS PER R403.1.4 FBC RES.
 PLEASE SEE THAT THE ELEVATION DRAWINGS ON A/2 SHOWS THE
 FINISHED GRADE AT 36" BELOW FIN FLOOR AND THE
 MONOLITHIC FOUNDATION IS ONLY 20" DEEP.
  
 8)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 9)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN
 COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES.
  
 10)TO CONFORM TO THE ZONING (SEE ZONING REVIEW)
 REGULATIONS THE ADDITION WALL THAT TIES INTO THE
 EXISTING BUILDING ON THE SOUTH SIDE WILL BE REQUIRED TO
 JOG OVER SO THAT THE BACK CORNER IS NOT ANY CLOSER TO
 THE PROPERTY LINE THAN THE EXISTING BUILDING 3.43 FEET.
 SEE THAT THE PROPOSED DISTANCE WOULD BE 3.31 THUS
 INCREASING THE NONCONFORMITY.
  
 11)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER
 R313.1.1 FBC RES.
  
 12)PROVIDE MIN ROOF SHEATHING ATTACHMENT
 PER R803.2.3.1 FBC RES. SHALL BE 8D RING SHANK AT 6"
 O/C EDGES AND FIELD AND 4" O/C EDGES AND FIELD IN ZONES
 2 & 3
  
 13)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW